1910.106(g)(9): Fire Extinguishers at Service Stations

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated noviembre 1, 2026 3 min read

In plain words:

Each service station must have at least one fire extinguisher with a minimum approved classification of 6 B, C. Extinguishers must be placed so one is within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.

Key takeaways

  • 1910.106(g)(9) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart H).
  • OSHA cited it 21 times in the last 3 years, in 21 inspections, with $7,408 in current penalties.
  • Most citations: TN (8), CT (6), GA (4).
  • Related part: 1910.106(g) Service stations (188 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.106(g)(9) ↓

21citations, 3 years
$7,408current penalties
21inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.106(g)(9) ("Fire control") is one requirement inside 1910.106 Flammable liquids, an OSHA general industry standard (Part 1910, Subpart H). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room. 21 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.106.

See every company cited for this rule.

Export the list: 21 inspections cited 1910.106(g)(9) in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Where and how often it was cited

YearCitations
20233
20248
20254
20266

Top states: TN (8), CT (6), GA (4), NC (1), MN (1)

Largest penalties

EmployerLocationPenalty for this rule
PROWOOD, LLCBRUNSWICK, GA$3,404
GEORGIA KAOLIN TERMINALS, INC.SAVANNAH, GA$2,979
110516 - NORTHLAND OUTDOOR SOLUTIONS LLCMANKATO, MN$270
TOWN OF CORNWALLCORNWALL, CT$250
TOWN OF DURHAMDURHAM, CT$180

Free toolbox talk

A 5-minute crew talk on 1910.106(g)(9), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.106(g)(9).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What size fire extinguisher is required at a service station?

At least one with a minimum approved classification of 6 B, C.

How close must an extinguisher be to a pump?

Within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.

Is one extinguisher always enough?

At least one is required, but they must be placed so every listed location is within 75 feet of one.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba