29 CFR 1910 · General Industry · Subpart H

1910.107(c)(5): No Electrical Equipment Where Residue Builds Up

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 20, 2026 3 min read

In plain words:

Unless specifically approved for locations with both readily ignitable residue and explosive vapors, no electrical equipment may be in any spraying area where combustible residues may readily accumulate. The only exception is wiring in rigid conduit or in boxes or fittings with no taps, splices or terminal connections.

Key takeaways

  • 1910.107(c)(5) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart H).
  • OSHA cited it 56 times in the last 3 years, in 56 inspections, with $67,949 in current penalties.
  • Most citations: TN (11), MI (8), VA (5).
  • Related part: 1910.107(c) Electrical and other sources of ignition (230 citations).
  • Free 5-minute toolbox talk for your crew below.
56citations, 3 years
$67,949current penalties
56inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.107(c)(5) ("Combustible residues, areas") is one requirement inside 1910.107 Spray finishing using flammable and combustible materials, an OSHA general industry standard (Part 1910, Subpart H). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections. 56 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.107.

Where and how often it was cited

YearCitations
20233
202421
202522
202610

Top states: TN (11), MI (8), VA (5), MN (4), RI (3)

Largest penalties

EmployerLocationPenalty for this rule
ELECTRO-MECHANICAL, LLC DBA FEDERAL PACIFICBRISTOL, VA$7,707
RAYMOND STORAGE CONCEPTS, INC.GROVEPORT, OH$6,671
ARCHITECTURAL GRAPHICS, INC.VIRGINIA BEACH, VA$5,723
CPX2023XT3633X0123 - BROWN & BROWN NISSAN INC. DBA AUTONATION NISSAN TEMPETEMPE, AZ$5,469
AMARAL CUSTOM FABRICATIONS INC.RUMFORD, RI$5,323

Free toolbox talk

A 5-minute crew talk on 1910.107(c)(5), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.107(c)(5).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Can electrical equipment be in a spray area with residue buildup?

No, unless it is specifically approved for locations with both readily ignitable residue and explosive vapors.

What wiring is allowed?

Wiring in rigid conduit or in boxes or fittings containing no taps, splices or terminal connections.

Why is this rule important?

Combustible residue and vapors in spray areas can be ignited by electrical equipment.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba