29 CFR 1910 · General Industry · Subpart H

1910.110(b)(6)(ii): OSHA rule

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated noviembre 6, 2026 3 min read

Key takeaways

  • 1910.110(b)(6)(ii) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart H).
  • OSHA cited it 4 times in the last 3 years, in 4 inspections, with $19,186 in current penalties.
  • Related part: 1910.110(b) Basic rules (79 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.110(b)(6)(ii) ↓

4citations, 3 years
$19,186current penalties
4inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. About this page

What this rule covers

29 CFR 1910.110(b)(6)(ii) is one requirement inside 1910.110 Storage and handling of liquefied petroleum gases, an OSHA general industry standard (Part 1910, Subpart H). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(ii) Each individual container shall be located with respect to the nearest important building or group of buildings in accordance with Table H-23. 4 citations

Table H-23

Water capacity per container Minimum distances
Containers Between aboveground containers
Underground Aboveground
Less than 125 gals. 1 10 feet None None.
125 to 250 gals 10 feet 10 feet None.
251 to 500 gals 10 feet 10 feet 3 feet.
501 to 2,000 gals 25 feet 2 25 feet 2 3 feet.
2,001 to 30,000 gals 50 feet 50 feet 5 feet.
30,001 to 70,000 gals 50 feet 75 feet. 3
70,001 to 90,000 gals 50 feet 100 feet. 3
1 If the aggregate water capacity of a multi-container installation at a consumer site is 501 gallons or greater, the minimum distance shall comply with the appropriate portion of this table, applying the aggregate capacity rather than the capacity per container. If more than one installation is made, each installation shall be separated from another installation by at least 25 feet. Do not apply the MINIMUM DISTANCES BETWEEN ABOVE-GROUND CONTAINERS to such installations.
2 The above distance requirements may be reduced to not less than 10 feet for a single container of 1,200 gallons water capacity or less, providing such a container is at least 25 feet from any other LP-Gas container of more than 125 gallons water capacity.
3 1⁄4 of sum of diameters of adjacent containers.

Source: eCFR, text current as of 2026-10-15. Read all of 1910.110.

See every company cited for this rule.

Export the list: 4 inspections cited 1910.110(b)(6)(ii) in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Where and how often it was cited

Free toolbox talk

A 5-minute crew talk on 1910.110(b)(6)(ii), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.110(b)(6)(ii).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba