1910.124(b): OSHA rule
Key takeaways
- 1910.124(b) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart H).
- OSHA cited it 4 times in the last 3 years, in 4 inspections, with $10,166 in current penalties.
- Related part: 1910.124(b)(4) (2 citations).
- Free 5-minute toolbox talk for your crew below.
Get the free 5-minute toolbox talk on 1910.124(b) ↓
In this article
What this rule covers
29 CFR 1910.124(b) is one requirement inside 1910.124 General requirements for dipping and coating operations, an OSHA general industry standard (Part 1910, Subpart H). It includes 13 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.
Official text
(b) What ventilation requirements apply to vapor areas? 4 citations
(1) The ventilation that you provide to a vapor area must keep the airborne concentration of any substance below 25% of its LFL. Open (b)(1)
(2) When a liquid in a dip tank creates an exposure hazard covered by a standard listed in subpart Z of this part, you must control worker exposure as required by that standard. 1 citations
(3) You may use a tank cover or material that floats on the surface of the liquid in a dip tank to replace or supplement ventilation. The method or combination of methods you choose must maintain the airborne concentration of the hazardous material and the worker's exposure within the limits specified in paragraphs (b)(1) and (b)(2) of this section.
(4) When you use mechanical ventilation, it must conform to the following standards that are incorporated by reference as specified in § 1910.6: Open (b)(4) 2 citations
(i) ANSI Z9.2-1979, Fundamentals Governing the Design and Operation of Local Exhaust Systems;
(ii) NFPA 34-1995, Standard for Dip Tanks Containing Flammable or Combustible Liquids; Open (b)(4)(ii) 2 citations
(iii) ACGIH's “Industrial Ventilation: A Manual of Recommended Practice” (22nd ed., 1995); or
(iv) ANSI Z9.1-1971, Practices for Ventilation and Operation of Open-Surface Tanks, and NFPA 34-1966, Standard for Dip Tanks Containing Flammable or Combustible Liquids.
(5) When you use mechanical ventilation, it must draw the flow of air into a hood or exhaust duct. 1 citations
(6) When you use mechanical ventilation, each dip tank must have an independent exhaust system unless the combination of substances being removed will not cause a:
(i) Fire;
(ii) Explosion; or
(iii) Chemical reaction.
Source: eCFR, text current as of 2026-10-15. Read all of 1910.124.
Export the list: 4 inspections cited 1910.124(b) in the last 3 years, with employer, location, penalty and date.
Purple Belt, $59/moWhere and how often it was cited
Free toolbox talk
A 5-minute crew talk on 1910.124(b), plus alerts when this rule changes. Free.
OSHA interpretation letters
None exist. OSHA has not published a letter of interpretation for 1910.124(b).
Related parts of this rule
- 1910.124(b)(4) 2 citations
- 1910.124(b)(4)(ii) 2 citations
- 1910.124(b)(1)
Get your crew competent
Trainers on Black Belt Safety: Marc Harvey
Trainers and suppliers: feature your business on this rule for $25/month.
About this page
Sources
- 29 CFR 1910.124 (eCFR), text current as of 2026-10-15
- U.S. Department of Labor enforcement data: OSHA inspections, citations and accident records, copied nightly; data as of 2026-11-06
3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.