1910.137(c)(2)(viii): Periodic Electrical Testing of Rubber Protective Equipment

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated noviembre 1, 2026 3 min read

In plain words:

Employers must have electrical protective equipment tested electrically on a regular schedule, using the test voltages and maximum intervals between tests listed in Tables I-4 and I-5.

Key takeaways

  • 1910.137(c)(2)(viii) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart I).
  • OSHA cited it 29 times in the last 3 years, in 29 inspections, with $128,968 in current penalties.
  • 2 deaths are linked to inspections that cited this rule.
  • Most citations: OH (7), TX (4), VA (3).
  • Related part: 1910.137(c) In-service care and use of electrical protective equipment (36 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.137(c)(2)(viii) ↓

29citations, 3 years
$128,968current penalties
29inspections
2linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.137(c)(2)(viii) is one requirement inside 1910.137 Electrical protective equipment, an OSHA general industry standard (Part 1910, Subpart I). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(viii) Electrical protective equipment shall be subjected to periodic electrical tests. Test voltages and the maximum intervals between tests shall be in accordance with Table I-4 and Table I-5. 29 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.137.

See every company cited for this rule.

Export the list: 29 inspections cited 1910.137(c)(2)(viii) in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Injuries linked to this rule

2 deaths are linked to inspections where OSHA cited 1910.137(c)(2)(viii).

Employee is killed when electrocuted
2024-06-19 · Fatal · COALING, AL

At 1:30 p.m. on June 19, 2024, an employee was electrocuted while accomplishing maintenance on a 7.2kV distribution line. The employee was killed.

See all 2 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
20233
202411
202511
20264

Top states: OH (7), TX (4), VA (3), TN (3), WI (2)

Largest penalties

EmployerLocationPenalty for this rule
HUBBELL INC.READING, PA$18,000
DESERT DIAMOND CASINO AND ENTERTAINMENTSAHUARITA, AZ$16,000
THE GOODYEAR TIRE & RUBBER COMPANYDANVILLE, VA$15,875
DEXTER FORTSON ASSOCIATES, INC.COALING, AL$9,598
DRYLOCK TECHNOLOGIES, LTD.EAU CLAIRE, WI$8,228

Free toolbox talk

A 5-minute crew talk on 1910.137(c)(2)(viii), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.137(c)(2)(viii).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Does electrical protective equipment need regular testing?

Yes. It must be subjected to periodic electrical tests.

Where are the test voltages and intervals listed?

In Table I-4 and Table I-5 of 1910.137.

Who is responsible for the testing?

The employer must make sure the equipment is tested as the rule requires.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba