In plain words:

Approved protective equipment in fuel-gas piping must prevent excessive oxygen back pressure in the fuel-gas supply. Devices go in the main line, at branch heads or at withdrawal points, and back-pressure protection is an approved pressure-relief device set no higher than the lower rating of the backflow or flashback device, located downstream of them. Its vent must be at least as large as the inlet, avoid low points, stay away from ignition sources and end in a hood or bend.

Key takeaways

  • 1910.253(e)(3)(ii)(C) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart Q).
  • OSHA cited it 24 times in the last 3 years, in 24 inspections, with $128,955 in current penalties.
  • 1 death is linked to inspections that cited this rule.
  • Most citations: NJ (19), IL (2), AL (1).
  • Related part: 1910.253(e) Protective equipment, hose, and regulators (54 citations).
  • Free 5-minute toolbox talk for your crew below.
24citations, 3 years
$128,955current penalties
24inspections
1linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.253(e)(3)(ii)(C) is one requirement inside 1910.253 Oxygen-fuel gas welding and cutting, an OSHA general industry standard (Part 1910, Subpart Q). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(C) Excessive back pressure of oxygen in the fuel-gas supply system. The three functions of the protective equipment may be combined in one device or may be provided by separate devices. 24 citations

(1) The protective equipment shall be located in the main supply line, as in Figure Q-1 or at the head of each branch line, as in Figure Q-2 or at each location where fuel-gas is withdrawn, as in Figure Q-3. Where branch lines are of 2-inch pipe size or larger or of substantial length, protective equipment (designated as PF) shall be located as shown in either Q-2 and Q-3.

(2) Backflow protection shall be provided by an approved device that will prevent oxygen from flowing into the fuel-gas system or fuel from flowing into the oxygen system (see SF, Figures Q-1 and Q-2).

(3) Flash-back protection shall be provided by an approved device that will prevent flame from passing into the fuel-gas system.

(4) Back-pressure protection shall be provided by an approved pressure-relief device set at a pressure not greater than the pressure rating of the backflow or the flashback protection device, whichever is lower. The pressure-relief device shall be located on the downstream side of the backflow and flashback protection devices. The vent from the pressure-relief device shall be at least as large as the relief device inlet and shall be installed without low points that may collect moisture. If low points are unavoidable, drip pots with drains closed with screw plugs or caps shall be installed at the low points. The vent terminus shall not endanger personnel or property through gas discharge; shall be located away from ignition sources; and shall terminate in a hood or bend.

Source: eCFR, text current as of 2026-10-15. Read all of 1910.253.

Injuries linked to this rule

1 death is linked to inspections where OSHA cited 1910.253(e)(3)(ii)(C).

Employee dies of blunt trauma in fall from inclined conveyor
2024-10-22 · Fatal · LIMA, OH

At 4:00 p.m. on October 22, 2024, an employee working as a machine maintenance technician was on an inclined conveyor preparing to maintain its gearbox. The employee was on top of the "naturals" conveyor (#C8) associated with the Colorbiotics mulch dye machine while a coworker…

Where and how often it was cited

YearCitations
202411
20255
20268

Top states: NJ (19), IL (2), AL (1), VT (1), OH (1)

Largest penalties

EmployerLocationPenalty for this rule
RESOURCE RECYCLING, INC.LIMA, OH$11,585
HACKETTSTOWN PUBLIC SCHOOLSHACKETTSTOWN, NJ$7,000
NJ DEPARTMENT OF ENVIRONMENTAL PROTECTIONCOLUMBIA, NJ$7,000
NEW JERSEY TURNPIKE AUTHORITYMULLICA HILL, NJ$7,000
BOROUGH OF GLASSBORO PUBLIC SCHOOL DISTRICTGLASSBORO, NJ$7,000

Free toolbox talk

A 5-minute crew talk on 1910.253(e)(3)(ii)(C), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.253(e)(3)(ii)(C).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What sets the relief device pressure?

It must be set no higher than the pressure rating of the backflow or flashback device, whichever is lower.

Where must the relief vent end?

Where gas discharge will not endanger personnel or property, away from ignition sources, ending in a hood or bend.

Can the three protection functions be in one device?

Yes, they may be combined in one device or provided by separate devices.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba