29 CFR 1910 · General Industry · Subpart R

1910.269(l)(1)(iii): Treat Lines as Energized

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 24, 2026 3 min read

In plain words:

Workers must consider and treat electric lines and equipment as energized unless they have been deenergized under the rule's deenergizing procedures in paragraph (d) or (m).

Key takeaways

  • 1910.269(l)(1)(iii) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart R).
  • OSHA cited it 5 times in the last 3 years, in 5 inspections, with $39,287 in current penalties.
  • 1 death is linked to inspections that cited this rule.
  • Related part: 1910.269(l) Working on or near exposed energized parts (75 citations).
  • Free 5-minute toolbox talk for your crew below.
5citations, 3 years
$39,287current penalties
5inspections
1linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.269(l)(1)(iii) is one requirement inside 1910.269 Electric power generation, transmission, and distribution, an OSHA general industry standard (Part 1910, Subpart R). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(iii) Electric lines and equipment shall be considered and treated as energized unless they have been deenergized in accordance with paragraph (d) or (m) of this section. 5 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.269.

Injuries linked to this rule

1 death is linked to inspections where OSHA cited 1910.269(l)(1)(iii).

Employee dies when electrocuted restoring power to pedestal
2024-11-20 · Fatal · SANFORD, NC

On November 24, 2024, an employee working for a power company was responding to a call of a power outage for customers in an established neighborhood. The employee and a coworker determined that there was no power travelling from one pedestal to another pedestal. A…

Where and how often it was cited

Free toolbox talk

A 5-minute crew talk on 1910.269(l)(1)(iii), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.269(l)(1)(iii).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

When can an electric line be treated as deenergized?

Only after it has been deenergized following paragraph (d) or (m) of 1910.269.

What if a line looks dead?

It must still be treated as energized until it has been deenergized under the required procedures.

Does this rule apply to equipment as well as lines?

Yes. It covers both electric lines and equipment.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba