29 CFR 1910 · General Industry · Subpart D

1910.27: Scaffolds and Rope Descent Systems

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated noviembre 6, 2026 3 min read

In plain words:

Scaffolds in general industry must meet the construction scaffold rules in 29 CFR 1926 subpart L. Before a rope descent system is used, the building owner must tell the employer in writing that each anchorage can support at least 5,000 pounds in any direction for each employee attached, and employers must ensure proper use, training and inspection at the start of each workshift.

Key takeaways

  • 1910.27 is part of OSHA's general industry standards (29 CFR Part 1910, Subpart D).
  • OSHA cited it 67 times in the last 3 years, in 58 inspections, with $511,036 in current penalties.
  • 2 deaths are linked to inspections that cited this rule.
  • Most citations: NV (8), NY (8), VA (7).
  • Most-cited part: 1910.27(a) Scaffolds (44 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.27 ↓

67citations, 3 years
$511,036current penalties
58inspections
2linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Most-cited parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.27, "Scaffolds and rope descent systems", is an OSHA general industry standard (Part 1910, Subpart D). It has 20 numbered paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

Show the full text of 1910.27 (20 paragraphs)

(a) Scaffolds. Scaffolds used in general industry must meet the requirements in 29 CFR part 1926, subpart L (Scaffolds). Open (a) 44 citations

(b) Rope descent systems — Open (b) 23 citations

(1) Anchorages. Open (b)(1) 9 citations

(i) Before any rope descent system is used, the building owner must inform the employer, in writing that the building owner has identified, tested, certified, and maintained each anchorage so it is capable of supporting at least 5,000 pounds (2,268 kg), in any direction, for each employee attached. The information must be based on an annual inspection by a qualified person and certification of each anchorage by a qualified person, as necessary, and at least every 10 years. Open (b)(1)(i) 3 citations

(ii) The employer must ensure that no employee uses any anchorage before the employer has obtained written information from the building owner that each anchorage meets the requirements of paragraph (b)(1)(i) of this section. The employer must keep the information for the duration of the job. Open (b)(1)(ii) 6 citations

(iii) The requirements in paragraphs (b)(1)(i) and (ii) of this section must be implemented no later than November 20, 2017. Open (b)(1)(iii)

(2) Use of rope descent systems. The employer must ensure: Open (b)(2) 14 citations

(i) No rope descent system is used for heights greater than 300 feet (91 m) above grade unless the employer demonstrates that it is not feasible to access such heights by any other means or that those means pose a greater hazard than using a rope descent system; Open (b)(2)(i)

(ii) The rope descent system is used in accordance with instructions, warnings, and design limitations set by the manufacturer or under the direction of a qualified person; 1 citations

(iii) Each employee who uses the rope descent system is trained in accordance with § 1910.30;

(iv) The rope descent system is inspected at the start of each workshift that it is to be used. The employer must ensure damaged or defective equipment is removed from service immediately and replaced; Open (b)(2)(iv) 4 citations

(v) The rope descent system has proper rigging, including anchorages and tiebacks, with particular emphasis on providing tiebacks when counterweights, cornice hooks, or similar non-permanent anchorages are used; 3 citations

(vi) Each employee uses a separate, independent personal fall arrest system that meets the requirements of subpart I of this part; 2 citations

(vii) All components of each rope descent system, except seat boards, are capable of sustaining a minimum rated load of 5,000 pounds (22.2 kN). Seat boards must be capable of supporting a live load of 300 pounds (136 kg);

(viii) Prompt rescue of each employee is provided in the event of a fall;

(ix) The ropes of each rope descent system are effectively padded or otherwise protected, where they can contact edges of the building, anchorage, obstructions, or other surfaces, to prevent them from being cut or weakened; Open (b)(2)(ix) 4 citations

(x) Stabilization is provided at the specific work location when descents are greater than 130 feet (39.6 m);

(xi) No employee uses a rope descent system when hazardous weather conditions, such as storms or gusty or excessive wind, are present;

(xii) Equipment, such as tools, squeegees, or buckets, is secured by a tool lanyard or similar method to prevent it from falling; and

(xiii) The ropes of each rope descent system are protected from exposure to open flames, hot work, corrosive chemicals, and other destructive conditions.

[81 FR 82981, Nov. 18, 2016, as amended at 84 FR 68796, Dec. 17, 2019]

Source: eCFR, text current as of 2026-10-15.

See every company cited for this rule.

Export the list: 58 inspections cited 1910.27 in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Injuries linked to this rule

2 deaths are linked to inspections where OSHA cited 1910.27.

Employee installing lighting fixture dies when electrocuted
2024-08-20 · Fatal · EL PASO, TX

At 12:11 p.m. on August 20, 2024, an employee working for a food manufacturer was installing a lighting fixture on an energized system. The employee contacteda live wire and was electrocuted. The employee died as a result of his injuries.

See all 2 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
20234
202417
202522
202624

Top states: NV (8), NY (8), VA (7), TX (4), IL (4)

Largest penalties

EmployerLocationPenalty for this rule
SHED'S DIRECT, LLCDANVILLE, VA$126,980
159822 - BURNS TREE AND CRANE, LLCHORSE SHOE, NC$59,580
VERIZON SERVICES CORP.LIVERPOOL, NY$34,050
SKY SAFETY, INC. / HI-RISE, INC.BOSTON, MA$32,500
SPEEDY GONZALEZ LANDSCAPING, INC.CHICAGO, IL$15,625

Free toolbox talk

A 5-minute crew talk on 1910.27, plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.27.

Most-cited parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How strong must rope descent anchorages be?

Capable of supporting at least 5,000 pounds (2,268 kg), in any direction, for each employee attached.

Can a rope descent system be used above 300 feet?

Not for heights greater than 300 feet above grade unless the employer shows other means are not feasible or pose a greater hazard.

How often is a rope descent system inspected?

At the start of each workshift that it is to be used.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba