29 CFR 1910 · General Industry · Subpart D

1910.29: Fall Protection System Criteria in General Industry

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated noviembre 6, 2026 3 min read

In plain words:

Employers must make sure fall protection and falling object protection systems meet set design and use criteria, and install them before workers start work that needs them. Guardrails must have a top edge 42 inches high, plus or minus 3 inches, with midrails or equal members, and must hold at least 200 pounds at the top rail and 150 pounds on midrails.

Key takeaways

  • 1910.29 is part of OSHA's general industry standards (29 CFR Part 1910, Subpart D).
  • OSHA cited it 874 times in the last 3 years, in 705 inspections, with $1,951,738 in current penalties.
  • 11 deaths are linked to inspections that cited this rule.
  • Most citations: OR (61), IL (61), MI (59).
  • Most-cited part: 1910.29(b) Guardrail systems (631 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.29 ↓

874citations, 3 years
$1,951,738current penalties
705inspections
11linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Most-cited parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.29, "Fall protection systems and falling object protection—criteria and practices", is an OSHA general industry standard (Part 1910, Subpart D). It has 92 numbered paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

Show the full text of 1910.29 (92 paragraphs)

(a) General requirements. The employer must: Open (a) 20 citations

(1) Ensure each fall protection system and falling object protection, other than personal fall protection systems, that this part requires meets the requirements in this section. The employer must ensure each personal fall protection system meets the requirements in subpart I of this part; and 5 citations

(2) Provide and install all fall protection systems and falling object protection this subpart requires, and comply with the other requirements in this subpart before any employee begins work that necessitates fall or falling object protection. Open (a)(2) 15 citations

(b) Guardrail systems. The employer must ensure guardrail systems meet the following requirements: Open (b) 631 citations

(1) The top edge height of top rails, or equivalent guardrail system members, are 42 inches (107 cm), plus or minus 3 inches (8 cm), above the walking-working surface. The top edge height may exceed 45 inches (114 cm), provided the guardrail system meets all other criteria of paragraph (b) of this section (see Figure D-11 of this section). Open (b)(1) 207 citations

(2) Midrails, screens, mesh, intermediate vertical members, solid panels, or equivalent intermediate members are installed between the walking-working surface and the top edge of the guardrail system as follows when there is not a wall or parapet that is at least 21 inches (53 cm) high: Open (b)(2) 273 citations

(i) Midrails are installed at a height midway between the top edge of the guardrail system and the walking-working surface; Open (b)(2)(i) 115 citations

(ii) Screens and mesh extend from the walking-working surface to the top rail and along the entire opening between top rail supports;

(iii) Intermediate vertical members (such as balusters) are installed no more than 19 inches (48 cm) apart; and 1 citations

(iv) Other equivalent intermediate members (such as additional midrails and architectural panels) are installed so that the openings are not more than 19 inches (48 cm) wide. 8 citations

(3) Guardrail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in a downward or outward direction within 2 inches (5 cm) of the top edge, at any point along the top rail. Open (b)(3) 47 citations

(4) When the 200-pound (890-N) test load is applied in a downward direction, the top rail of the guardrail system must not deflect to a height of less than 39 inches (99 cm) above the walking-working surface. 3 citations

(5) Midrails, screens, mesh, intermediate vertical members, solid panels, and other equivalent intermediate members are capable of withstanding, without failure, a force of at least 150 pounds (667 N) applied in any downward or outward direction at any point along the intermediate member. Open (b)(5) 12 citations

(6) Guardrail systems are smooth-surfaced to protect employees from injury, such as punctures or lacerations, and to prevent catching or snagging of clothing. Open (b)(6) 10 citations

(7) The ends of top rails and midrails do not overhang the terminal posts, except where the overhang does not pose a projection hazard for employees.

(8) Steel banding and plastic banding are not used for top rails or midrails.

(9) Top rails and midrails are at least 0.25-inches (0.6 cm) in diameter or in thickness. 1 citations

(10) When guardrail systems are used at hoist areas, a removable guardrail section, consisting of a top rail and midrail, are placed across the access opening between guardrail sections when employees are not performing hoisting operations. The employer may use chains or gates instead of a removable guardrail section at hoist areas if the employer demonstrates the chains or gates provide a level of safety equivalent to guardrails. Open (b)(10) 20 citations

(11) When guardrail systems are used around holes, they are installed on all unprotected sides or edges of the hole. 2 citations

(12) For guardrail systems used around holes through which materials may be passed: 1 citations

(i) When materials are being passed through the hole, not more than two sides of the guardrail system are removed; and

(ii) When materials are not being passed through the hole, the hole must be guarded by a guardrail system along all unprotected sides or edges or closed over with a cover. 1 citations

(13) When guardrail systems are used around holes that serve as points of access (such as ladderways), the guardrail system opening: Open (b)(13) 52 citations

(i) Has a self-closing gate that slides or swings away from the hole, and is equipped with a top rail and midrail or equivalent intermediate member that meets the requirements in paragraph (b) of this section; or Open (b)(13)(i) 33 citations

(ii) Is offset to prevent an employee from walking or falling into the hole;

(14) Guardrail systems on ramps and runways are installed along each unprotected side or edge. 2 citations

(15) Manila or synthetic rope used for top rails or midrails are inspected as necessary to ensure that the rope continues to meet the strength requirements in paragraphs (b)(3) and (5) of this section.

The criteria and practices requirements for guardrail systems on scaffolds are contained in 29 CFR part 1926, subpart L.

(c) Safety net systems. The employer must ensure each safety net system meets the requirements in 29 CFR part 1926, subpart M. 6 citations

(d) Designated areas. 7 citations

(1) When the employer uses a designated area, the employer must ensure: 5 citations

(i) Employees remain within the designated area while work operations are underway; and 1 citations

(ii) The perimeter of the designated area is delineated with a warning line consisting of a rope, wire, tape, or chain that meets the requirements of paragraphs (d)(2) and (3) of this section. 3 citations

(2) The employer must ensure each warning line: 2 citations

(i) Has a minimum breaking strength of 200 pounds (0.89 kN);

(ii) Is installed so its lowest point, including sag, is not less than 34 inches (86 cm) and not more than 39 inches (99 cm) above the walking-working surface; 1 citations

(iii) Is supported in such a manner that pulling on one section of the line will not result in slack being taken up in adjacent sections causing the line to fall below the limits specified in paragraph (d)(2)(ii) of this section;

(iv) Is clearly visible from a distance of 25 feet (7.6 m) away, and anywhere within the designated area;

(v) Is erected as close to the work area as the task permits; and

(vi) Is erected not less than 6 feet (1.8 m) from the roof edge for work that is both temporary and infrequent, or not less than 15 feet (4.6 m) for other work. 1 citations

(3) When mobile mechanical equipment is used to perform work that is both temporary and infrequent in a designated area, the employer must ensure the warning line is erected not less than 6 feet (1.8 m) from the unprotected side or edge that is parallel to the direction in which the mechanical equipment is operated, and not less than 10 feet (3 m) from the unprotected side or edge that is perpendicular to the direction in which the mechanical equipment is operated.

(e) Covers. The employer must ensure each cover for a hole in a walking-working surface: Open (e) 29 citations

(1) Is capable of supporting without failure, at least twice the maximum intended load that may be imposed on the cover at any one time; and 6 citations

(2) Is secured to prevent accidental displacement. Open (e)(2) 15 citations

(f) Handrails and stair rail systems. The employer must ensure: Open (f) 130 citations

(1) Height criteria. Open (f)(1) 26 citations

(i) Handrails are not less than 30 inches (76 cm) and not more than 38 inches (97 cm), as measured from the leading edge of the stair tread to the top surface of the handrail (see Figure D-12 of this section). Open (f)(1)(i) 8 citations

(ii) The height of stair rail systems meets the following: Open (f)(1)(ii) 8 citations

(A) The height of stair rail systems installed before January 17, 2017 is not less than 30 inches (76 cm) from the leading edge of the stair tread to the top surface of the top rail; and Open (f)(1)(ii)(a) 4 citations

(B) The height of stair rail systems installed on or after January 17, 2017 is not less than 42 inches (107 cm) from the leading edge of the stair tread to the top surface of the top rail. Open (f)(1)(ii)(b) 4 citations

(iii) The top rail of a stair rail system may serve as a handrail only when: Open (f)(1)(iii) 10 citations

(A) The height of the stair rail system is not less than 36 inches (91 cm) and not more than 38 inches (97 cm) as measured at the leading edge of the stair tread to the top surface of the top rail (see Figure D-13 of this section); and Open (f)(1)(iii)(a) 8 citations

(B) The top rail of the stair rail system meets the other handrail requirements in paragraph (f) of this section. Open (f)(1)(iii)(b)

(2) Finger clearance. The minimum clearance between handrails and any other object is 2.25 inches (5.7 cm). 8 citations

(3) Surfaces. Handrails and stair rail systems are smooth-surfaced to protect employees from injury, such as punctures or lacerations, and to prevent catching or snagging of clothing. 4 citations

(4) Openings in stair rails. No opening in a stair rail system exceeds 19 inches (48 cm) at its least dimension. Open (f)(4) 73 citations

(5) Handhold. Handrails have the shape and dimension necessary so that employees can grasp the handrail firmly. 3 citations

(6) Projection hazards. The ends of handrails and stair rail systems do not present any projection hazards.

(7) Strength criteria. Handrails and the top rails of stair rail systems are capable of withstanding, without failure, a force of at least 200 pounds (890 N) applied in any downward or outward direction within 2 inches (5 cm) of any point along the top edge of the rail. Open (f)(7) 15 citations

(g) Cages, wells, and platforms used with fixed ladders. The employer must ensure: Open (g) 1 citations

(1) Cages and wells installed on fixed ladders are designed, constructed, and maintained to permit easy access to, and egress from, the ladder that they enclose (see Figures D-14 and D-15 of this section);

(2) Cages and wells are continuous throughout the length of the fixed ladder, except for access, egress, and other transfer points;

(3) Cages and wells are designed, constructed, and maintained to contain employees in the event of a fall, and to direct them to a lower landing; and Open (g)(3) 1 citations

(4) Platforms used with fixed ladders provide a horizontal surface of at least 24 inches by 30 inches (61 cm by 76 cm). Open (g)(4)

Section 1910.28 establishes the requirements that employers must follow on the use of cages and wells as a means of fall protection.

(h) Outdoor advertising. This paragraph (h) applies only to employers engaged in outdoor advertising operations (see § 1910.28(b)(10)). Employers must ensure that each employee who climbs a fixed ladder without fall protection: Open (h)

(1) Is physically capable, as demonstrated through observations of actual climbing activities or by a physical examination, to perform the duties that may be assigned, including climbing fixed ladders without fall protection;

(2) Has successfully completed a training or apprenticeship program that includes hands-on training on the safe climbing of ladders and is retrained as necessary to maintain the necessary skills;

(3) Has the skill to climb ladders safely, as demonstrated through formal classroom training or on-the-job training, and performance observation; and

(4) Performs climbing duties as a part of routine work activity.

(i) Ladder safety systems. The employer must ensure:

(1) Each ladder safety system allows the employee to climb up and down using both hands and does not require that the employee continuously hold, push, or pull any part of the system while climbing;

(2) The connection between the carrier or lifeline and the point of attachment to the body harness or belt does not exceed 9 inches (23 cm);

(3) Mountings for rigid carriers are attached at each end of the carrier, with intermediate mountings spaced, as necessary, along the entire length of the carrier so the system has the strength to stop employee falls;

(4) Mountings for flexible carriers are attached at each end of the carrier and cable guides for flexible carriers are installed at least 25 feet (7.6 m) apart but not more than 40 feet (12.2 m) apart along the entire length of the carrier;

(5) The design and installation of mountings and cable guides does not reduce the design strength of the ladder; and

(6) Ladder safety systems and their support systems are capable of withstanding, without failure, a drop test consisting of an 18-inch (41-cm) drop of a 500-pound (227-kg) weight.

(j) Personal fall protection systems. Body belts, harnesses, and other components used in personal fall arrest systems, work positioning systems, and travel restraint systems must meet the requirements of § 1910.140. 4 citations

(k) Protection from falling objects. Open (k) 46 citations

(1) The employers must ensure toeboards used for falling object protection: Open (k)(1) 44 citations

(i) Are erected along the exposed edge of the overhead walking-working surface for a length that is sufficient to protect employees below. Open (k)(1)(i) 14 citations

(ii) Have a minimum vertical height of 3.5 inches (9 cm) as measured from the top edge of the toeboard to the level of the walking-working surface. 1 citations

(iii) Do not have more than a 0.25-inch (0.5-cm) clearance or opening above the walking-working surface. 1 citations

(iv) Are solid or do not have any opening that exceeds 1 inch (3 cm) at its greatest dimension.

(v) Have a minimum height of 2.5 inches (6 cm) when used around vehicle repair, service, or assembly pits. Toeboards may be omitted around vehicle repair, service, or assembly pits when the employer can demonstrate that a toeboard would prevent access to a vehicle that is over the pit.

(vi) Are capable of withstanding, without failure, a force of at least 50 pounds (222 N) applied in any downward or outward direction at any point along the toeboard.

(2) The employer must ensure: 2 citations

(i) Where tools, equipment, or materials are piled higher than the top of the toeboard, paneling or screening is installed from the toeboard to the midrail of the guardrail system and for a length that is sufficient to protect employees below. If the items are piled higher than the midrail, the employer also must install paneling or screening to the top rail and for a length that is sufficient to protect employees below; and 2 citations

(ii) All openings in guardrail systems are small enough to prevent objects from falling through the opening.

(3) The employer must ensure canopies used for falling object protection are strong enough to prevent collapse and to prevent penetration by falling objects.

(l) Grab handles. The employer must ensure each grab handle:

(1) Is not less than 12 inches (30 cm) long;

(2) Is mounted to provide at least 3 inches (8 cm) of clearance from the framing or opening; and

(3) Is capable of withstanding a maximum horizontal pull-out force equal to two times the maximum intended load or 200 pounds (890 N), whichever is greater.

[81 FR 82981, Nov. 18, 2016, as amended at 84 FR 68796, Dec. 17, 2019]

Source: eCFR, text current as of 2026-10-15.

See every company cited for this rule.

Export the list: 705 inspections cited 1910.29 in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Injuries linked to this rule

11 deaths are linked to inspections where OSHA cited 1910.29.

Employee dies from asphyxiation when engulfed in aggregate h
2025-01-24 · Fatal · GREENFIELD, MA

At 8:50 a.m. on January 24, 2025, Employee #1 was working as a construction laborer for a concrete supplier attempted to remove a blockage in a material storage bin. The aggregate that was filling the hopper became clogged. The employee attempted to clear the blockage…

See all 11 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
202334
2024305
2025337
2026198

Top states: OR (61), IL (61), MI (59), MD (58), NY (51)

Largest penalties

EmployerLocationPenalty for this rule
A. DUIE PYLE, INC.FAIRLESS HILLS, PA$33,100
317744972 - VALVOLINE LLCLEBANON, OR$29,147
SUPERIOR PLUS ENERGY SERVICES INC.OAK RIDGE, NJ$25,352
JOHNSONVILLE, LLCSHEBOYGAN FALLS, WI$23,170
317737975 - SOUTH COAST LUMBER COBROOKINGS, OR$23,056

Free toolbox talk

A 5-minute crew talk on 1910.29, plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.29.

Most-cited parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How high must a guardrail be in general industry?

The top edge must be 42 inches, plus or minus 3 inches, above the walking-working surface.

How much force must a guardrail top rail withstand?

At least 200 pounds applied downward or outward within 2 inches of the top edge, without dropping below 39 inches.

When must fall protection be installed?

Before any employee begins work that requires fall or falling object protection.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba