29 CFR 1910 · General Industry · Subpart S

1910.305(e): Electrical Enclosures for Damp or Wet Locations

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 20, 2026 3 min read

In plain words:

Employers must install cabinets, boxes, fittings and panelboard enclosures in damp or wet locations so water cannot enter and collect, mounted with at least 6.35 mm (0.25 in.) of airspace from the wall, except nonmetallic enclosures on concrete, masonry, tile or similar surfaces. Enclosures in wet locations must be weatherproof, and switches, breakers and switchboards in wet locations need weatherproof enclosures.

Key takeaways

  • 1910.305(e) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart S).
  • OSHA cited it 93 times in the last 3 years, in 92 inspections, with $152,235 in current penalties.
  • Most citations: NY (20), NJ (8), CT (7).
  • Related part: 1910.305(e)(1) Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures (85 citations).
  • Free 5-minute toolbox talk for your crew below.
93citations, 3 years
$152,235current penalties
92inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.305(e) ("Enclosures for damp or wet locations") is one requirement inside 1910.305 Wiring methods, components, and equipment for general use, an OSHA general industry standard (Part 1910, Subpart S). It includes 2 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(e) Enclosures for damp or wet locations — 93 citations

(1) Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures. Cabinets, cutout boxes, fittings, boxes, and panelboard enclosures in damp or wet locations shall be installed so as to prevent moisture or water from entering and accumulating within the enclosures and shall be mounted so there is at least 6.35-mm (0.25-in.) airspace between the enclosure and the wall or other supporting surface. However, nonmetallic enclosures may be installed without the airspace on a concrete, masonry, tile, or similar surface. The enclosures shall be weatherproof in wet locations. Open (e)(1) 85 citations

(2) Switches, circuit breakers, and switchboards. Switches, circuit breakers, and switchboards installed in wet locations shall be enclosed in weatherproof enclosures. 8 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.305.

Where and how often it was cited

YearCitations
20239
202436
202529
202619

Top states: NY (20), NJ (8), CT (7), MN (7), VA (6)

Largest penalties

EmployerLocationPenalty for this rule
DTOPPONCE, PR$14,000
EVERGREEN RECYCLING, LLCALBANY, NY$10,758
PPRCATANO, PR$9,457
159108 - COUNTY OF CASWELL SOLID WASTEYANCEYVILLE, NC$8,000
KRAFT HEINZMUSCATINE, IA$7,813

Free toolbox talk

A 5-minute crew talk on 1910.305(e), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.305(e).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How much airspace is required behind enclosures in wet or damp locations?

At least 6.35 mm (0.25 in.) between the enclosure and the wall or supporting surface.

What about switches and breakers in wet locations?

They must be enclosed in weatherproof enclosures.

Can nonmetallic boxes be mounted flat against concrete?

Yes. Nonmetallic enclosures may be installed without the airspace on concrete, masonry, tile or similar surfaces.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba