In plain words:

Flexible cords used with grounding-type equipment must contain an equipment grounding conductor. Plugs and receptacles must not be connected or altered in a way that breaks grounding continuity or lets the grounding pole fit current-carrying slots, and adapters that interrupt the grounding connection may not be used.

Key takeaways

  • 1910.334(a)(3) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart S).
  • OSHA cited it 80 times in the last 3 years, in 80 inspections, with $81,333 in current penalties.
  • 1 death is linked to inspections that cited this rule.
  • Most citations: NY (13), CT (10), TX (8).
  • Related part: 1910.334(a) Portable electric equipment (956 citations).
  • Free 5-minute toolbox talk for your crew below.
80citations, 3 years
$81,333current penalties
80inspections
1linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.334(a)(3) ("Grounding-type equipment") is one requirement inside 1910.334 Use of equipment, an OSHA general industry standard (Part 1910, Subpart S). It includes 3 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(3) Grounding-type equipment. 80 citations

(i) A flexible cord used with grounding-type equipment shall contain an equipment grounding conductor. Open (a)(3)(i) 52 citations

(ii) Attachment plugs and receptacles may not be connected or altered in a manner which would prevent proper continuity of the equipment grounding conductor at the point where plugs are attached to receptacles. Additionally, these devices may not be altered to allow the grounding pole of a plug to be inserted into slots intended for connection to the current-carrying conductors. Open (a)(3)(ii) 26 citations

(iii) Adapters which interrupt the continuity of the equipment grounding connection may not be used. 2 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.334.

Injuries linked to this rule

1 death is linked to inspections where OSHA cited 1910.334(a)(3).

Employee is electrocuted while operating winch
2024-05-08 · Fatal · LYFORD, TX

At 7:30 a.m. on May 8, 2024, Employee #1 was operating a hoisting winch at the wind turbine nacelle in preparation to elevate tool bags up the tower. During this operation, it appears that Employee #1 was electrocuted, which subsequentlyled to cardiac arrest. Emergency services…

Where and how often it was cited

YearCitations
20233
202432
202532
202613

Top states: NY (13), CT (10), TX (8), MI (7), ME (4)

Largest penalties

EmployerLocationPenalty for this rule
PREMIUM VELOCITY AUTO LLCLEAGUE CITY, TX$9,127
AMARU MOTORS LLCEL PASO, TX$9,000
DERIVA ENERGY LLCLYFORD, TX$8,066
MVP PLASTICS SA, LLCBROWNSVILLE, TX$6,951
BOROUGH OF POINT PLEASANT DPWPOINT PLEASANT BORO, NJ$5,400

Free toolbox talk

A 5-minute crew talk on 1910.334(a)(3), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.334(a)(3).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Must a cord for grounded equipment have a ground wire?

Yes. It must contain an equipment grounding conductor.

Can I cut the ground prong off a plug?

No. Plugs and receptacles may not be altered in a way that would prevent proper continuity of the equipment grounding conductor.

Can I use a cheater adapter?

No. Adapters that interrupt the continuity of the equipment grounding connection may not be used.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba