29 CFR 1910 · General Industry · Subpart S

1910.334(c): Safe Use of Electrical Test Instruments

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated noviembre 1, 2026 3 min read

In plain words:

Only qualified persons may do testing work on electric circuits or equipment. Test instruments, leads, cables, cords, probes and connectors must be visually inspected for defects and damage before use, removed from service if damaged until repaired and tested, and rated for the circuits and environment where they are used.

Key takeaways

  • 1910.334(c) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart S).
  • OSHA cited it 14 times in the last 3 years, in 11 inspections, with $72,065 in current penalties.
  • Most citations: IA (4), NJ (2), OH (1).
  • Related part: 1910.334(c)(1) Use (6 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.334(c) ↓

14citations, 3 years
$72,065current penalties
11inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.334(c) ("Test instruments and equipment") is one requirement inside 1910.334 Use of equipment, an OSHA general industry standard (Part 1910, Subpart S). It includes 3 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(c) Test instruments and equipment — 14 citations

(1) Use. Only qualified persons may perform testing work on electric circuits or equipment. Open (c)(1) 6 citations

(2) Visual inspection. Test instruments and equipment and all associated test leads, cables, power cords, probes, and connectors shall be visually inspected for external defects and damage before the equipment is used. If there is a defect or evidence of damage that might expose an employee to injury, the defective or damaged item shall be removed from service, and no employee may use it until repairs and tests necessary to render the equipment safe have been made. 5 citations

(3) Rating of equipment. Test instruments and equipment and their accessories shall be rated for the circuits and equipment to which they will be connected and shall be designed for the environment in which they will be used. 3 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.334.

See every company cited for this rule.

Export the list: 11 inspections cited 1910.334(c) in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Where and how often it was cited

YearCitations
20242
20255
20267

Top states: IA (4), NJ (2), OH (1), TN (1), GA (1)

Largest penalties

EmployerLocationPenalty for this rule
A09CS00000TJEZVAAY - MIDAMERICAN ENERGY COMPANYSALIX, IA$18,090
RESA POWER, LLCLEMONT, IL$16,550
RAPID PUMP & METER CO., INC.NEWARK, NJ$12,000
LOS LUNAS, VILLAGE OF, PARKS & RECREATION DEPARTMENTLOS LUNAS, NM$11,588
HOUSE OF CHEATHAM LLCSTONE MOUNTAIN, GA$6,453

Free toolbox talk

A 5-minute crew talk on 1910.334(c), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.334(c).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Who can test electric circuits?

Only qualified persons may perform testing work on electric circuits or equipment.

What do I check before using a meter?

Visually inspect the instrument and all test leads, cables, power cords, probes and connectors for external defects and damage.

Can I use any meter on any circuit?

No. Test instruments and accessories must be rated for the circuits and equipment they connect to and designed for the environment where they are used.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba