29 CFR 1910 · General Industry · Subpart E

1910.36(a): Exit Route Design and Construction

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated noviembre 5, 2026 3 min read

In plain words:

Employers must make exit routes a permanent part of the workplace. Exits must be separated by fire resistant materials, with a one-hour rating if the exit connects three or fewer stories and a two-hour rating if it connects four or more, and openings into an exit are limited and protected by self-closing, listed or approved fire doors.

Key takeaways

  • 1910.36(a) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart E).
  • OSHA cited it 18 times in the last 3 years, in 18 inspections, with $30,217 in current penalties.
  • Most citations: PR (5), IL (3), MA (3).
  • Related part: 1910.36(a)(3) Openings into an exit must be limited (13 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.36(a) ↓

18citations, 3 years
$30,217current penalties
18inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.36(a) ("Basic requirements") is one requirement inside 1910.36 Design and construction requirements for exit routes, an OSHA general industry standard (Part 1910, Subpart E). It includes 3 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(a) Basic requirements. Exit routes must meet the following design and construction requirements: 18 citations

(1) An exit route must be permanent. Each exit route must be a permanent part of the workplace. 1 citations

(2) An exit must be separated by fire resistant materials. Construction materials used to separate an exit from other parts of the workplace must have a one-hour fire resistance-rating if the exit connects three or fewer stories and a two-hour fire resistance-rating if the exit connects four or more stories. 4 citations

(3) Openings into an exit must be limited. An exit is permitted to have only those openings necessary to allow access to the exit from occupied areas of the workplace, or to the exit discharge. An opening into an exit must be protected by a self-closing fire door that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be listed or approved by a nationally recognized testing laboratory. Section 1910.155(c)(3)(iv)(A) of this part defines “listed” and § 1910.7 of this part defines a “nationally recognized testing laboratory.” Open (a)(3) 13 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.36.

See every company cited for this rule.

Export the list: 18 inspections cited 1910.36(a) in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Where and how often it was cited

YearCitations
202411
20256
20261

Top states: PR (5), IL (3), MA (3), RI (1), NV (1)

Largest penalties

EmployerLocationPenalty for this rule
AMBERCARESANTA FE, NM$6,622
AGI POST, INC.EAST BOSTON, MA$5,700
MUNICIPIO AUTONOMO DE COAMOCOAMO, PR$3,000
SOH-JUD - HOME MALUHIAHONOLULU, HI$2,954
DDECCOAMO, PR$2,550

Free toolbox talk

A 5-minute crew talk on 1910.36(a), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.36(a).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Can an exit route be temporary?

No. Each exit route must be a permanent part of the workplace.

What fire rating must exit separations have?

One-hour if the exit connects three or fewer stories, two-hour if it connects four or more stories.

What openings are allowed into an exit?

Only openings needed for access from occupied areas or to the exit discharge, protected by a self-closing fire door that stays closed or closes automatically in an emergency.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.