29 CFR 1910 · General Industry · Subpart G

1910.94(c)(6)(i): OSHA rule

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 4 min read

Key takeaways

  • 1910.94(c)(6)(i) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart G).
  • Related part: 1910.94(c) Spray finishing operations (30 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.94(c)(6)(i) ↓

In this article
  1. What this rule covers
  2. Official text
  3. Free toolbox talk
  4. OSHA interpretation letters
  5. Related parts of this rule
  6. Get your crew competent
  7. About this page

What this rule covers

29 CFR 1910.94(c)(6)(i) is one requirement inside 1910.94 Ventilation, an OSHA general industry standard (Part 1910, Subpart G). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(i) Except where a spray booth has an adequate air replacement system, the velocity of air into all openings of a spray booth shall be not less than that specified in Table G-10 for the operating conditions specified. An adequate air replacement system is one which introduces replacement air upstream or above the object being sprayed and is so designed that the velocity of air in the booth cross section is not less than that specified in Table G-10 when measured upstream or above the object being sprayed.

Table G-10—Minimum Maintained Velocities Into Spray Booths

Operating conditions for objects completely inside booth Crossdraft, f.p.m. Airflow velocities, f.p.m.
Design Range
Electrostatic and automatic airless operation contained in booth without operator Negligible 50 large booth 50-75
100 small booth 75-125
Air-operated guns, manual or automatic Up to 50 100 large booth 75-125
150 small booth 125-175
Air-operated guns, manual or automatic Up to 100 150 large booth 125-175
200 small booth 150-250
Notes:
(1) Attention is invited to the fact that the effectiveness of the spray booth is dependent upon the relationship of the depth of the booth to its height and width.
(2) Crossdrafts can be eliminated through proper design and such design should be sought. Crossdrafts in excess of 100fpm (feet per minute) should not be permitted.
(3) Excessive air pressures result in loss of both efficiency and material waste in addition to creating a backlash that may carry overspray and fumes into adjacent work areas.
(4) Booths should be designed with velocities shown in the column headed “Design.” However, booths operating with velocities shown in the column headed “Range” are in compliance with this standard.

Source: eCFR, text current as of 2026-10-15. Read all of 1910.94.

Free toolbox talk

A 5-minute crew talk on 1910.94(c)(6)(i), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.94(c)(6)(i).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by