1910.95(h): Audiometric test requirements
Key takeaways
- 1910.95(h) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart G).
- OSHA cited it 1 times in the last 3 years, in 1 inspections, with $240 in current penalties.
- Related part: 1910.95(h)(1) (1 citations).
- Free 5-minute toolbox talk for your crew below.
Get the free 5-minute toolbox talk on 1910.95(h) ↓
In this article
What this rule covers
29 CFR 1910.95(h) ("Audiometric test requirements") is one requirement inside 1910.95 Occupational noise exposure, an OSHA general industry standard (Part 1910, Subpart G). It includes 8 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.
Official text
(h) Audiometric test requirements. 1 citations
(1) Audiometric tests shall be pure tone, air conduction, hearing threshold examinations, with test frequencies including as a minimum 500, 1000, 2000, 3000, 4000, and 6000 Hz. Tests at each frequency shall be taken separately for each ear. Open (h)(1) 1 citations
(2) Audiometric tests shall be conducted with audiometers (including microprocessor audiometers) that meet the specifications of, and are maintained and used in accordance with, American National Standard Specification for Audiometers, S3.6-1969, which is incorporated by reference as specified in § 1910.6. Open (h)(2)
(3) Pulsed-tone and self-recording audiometers, if used, shall meet the requirements specified in appendix C: Audiometric Measuring Instruments. Open (h)(3)
(4) Audiometric examinations shall be administered in a room meeting the requirements listed in appendix D: Audiometric Test Rooms. Open (h)(4)
(5) Audiometer calibration. Open (h)(5)
(i) The functional operation of the audiometer shall be checked before each day's use by testing a person with known, stable hearing thresholds, and by listening to the audiometer's output to make sure that the output is free from distorted or unwanted sounds. Deviations of 10 decibels or greater require an acoustic calibration. Open (h)(5)(i)
(ii) Audiometer calibration shall be checked acoustically at least annually in accordance with appendix E: Acoustic Calibration of Audiometers. Test frequencies below 500 Hz and above 6000 Hz may be omitted from this check. Deviations of 15 decibels or greater require an exhaustive calibration. Open (h)(5)(ii)
(iii) An exhaustive calibration shall be performed at least every two years in accordance with sections 4.1.2; 4.1.3.; 4.1.4.3; 4.2; 4.4.1; 4.4.2; 4.4.3; and 4.5 of the American National Standard Specification for Audiometers, S3.6-1969. Test frequencies below 500 Hz and above 6000 Hz may be omitted from this calibration.
Source: eCFR, text current as of 2026-10-15. Read all of 1910.95.
Export the list: 1 inspections cited 1910.95(h) in the last 3 years, with employer, location, penalty and date.
Purple Belt, $59/moWhere and how often it was cited
Free toolbox talk
A 5-minute crew talk on 1910.95(h), plus alerts when this rule changes. Free.
OSHA interpretation letters
None exist. OSHA has not published a letter of interpretation for 1910.95(h).
Related parts of this rule
- 1910.95(h)(1) 1 citations
- 1910.95(h)(4)
- 1910.95(h)(5) Audiometer calibration
- 1910.95(h)(5)(i)
- 1910.95(h)(5)(ii)
- 1910.95(h)(2)
- 1910.95(h)(3)
Get your crew competent
Trainers on Black Belt Safety: Marc Harvey
Trainers and suppliers: feature your business on this rule for $25/month.
About this page
Sources
- 29 CFR 1910.95 (eCFR), text current as of 2026-10-15
- U.S. Department of Labor enforcement data: OSHA inspections, citations and accident records, copied nightly; data as of 2026-11-05
3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.