29 CFR 1926 · Construction · Subpart F

1926.150(c)(1)(iv): Fire Extinguishers on Each Floor

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 20, 2026 3 min read

In plain words:

Employers must provide one or more fire extinguishers rated not less than 2A on each floor of a construction project. In multistory buildings, at least one fire extinguisher must be located next to a stairway.

Key takeaways

  • 1926.150(c)(1)(iv) is part of OSHA's construction standards (29 CFR Part 1926, Subpart F).
  • OSHA cited it 82 times in the last 3 years, in 82 inspections, with $33,878 in current penalties.
  • Most citations: IN (56), OR (12), NC (5).
  • Related part: 1926.150(c) Portable firefighting equipment (369 citations).
  • Free 5-minute toolbox talk for your crew below.
82citations, 3 years
$33,878current penalties
82inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1926.150(c)(1)(iv) is one requirement inside 1926.150 Fire protection, an OSHA construction standard (Part 1926, Subpart F). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(iv) One or more fire extinguishers, rated not less than 2A, shall be provided on each floor. In multistory buildings, at least one fire extinguisher shall be located adjacent to stairway. 82 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1926.150.

Where and how often it was cited

YearCitations
20232
202429
202544
20267

Top states: IN (56), OR (12), NC (5), MA (3), VA (3)

Largest penalties

EmployerLocationPenalty for this rule
EARL GRAY AND SONS INCINDIANAPOLIS, IN$7,000
CLAYTON PROPERTIESCOLUMBUS, IN$2,800
DESIGN & BUILD ELECTRICAL CONTRACTORSWHITELAND, IN$2,800
MTZ FRAMING, LLCEAST BOSTON, MA$2,128
GOODFELLAS ELECTRIC COMPANYJEFFERSONVILLE, IN$1,600

Free toolbox talk

A 5-minute crew talk on 1926.150(c)(1)(iv), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1926.150(c)(1)(iv).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What rating must the extinguishers have?

Not less than 2A.

How many extinguishers are needed per floor?

One or more on each floor.

Where must an extinguisher be in a multistory building?

At least one must be located adjacent to a stairway.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba