29 CFR 1926 · Construction · Subpart J

1926.351: Arc Welding and Cutting Equipment

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated noviembre 6, 2026 3 min read

In plain words:

In construction, employers must use only manual electrode holders designed for arc welding and cutting and rated for the electrode current, with fully insulated grip and jaws. Welding cables must be completely insulated and flexible, free of repairs or splices within 10 feet of the electrode holder end except for standard insulated connectors or equal-quality splices, and cables needing repair must not be used.

Key takeaways

  • 1926.351 is part of OSHA's construction standards (29 CFR Part 1926, Subpart J).
  • OSHA cited it 32 times in the last 3 years, in 28 inspections, with $49,386 in current penalties.
  • 1 death is linked to inspections that cited this rule.
  • Most citations: VA (6), MD (6), NV (4).
  • Most-cited part: 1926.351(b) Welding cables and connectors (26 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1926.351 ↓

32citations, 3 years
$49,386current penalties
28inspections
1linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Most-cited parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1926.351, "Arc welding and cutting", is an OSHA construction standard (Part 1926, Subpart J). It has 22 numbered paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

Show the full text of 1926.351 (22 paragraphs)

(a) Manual electrode holders. Open (a) 2 citations

(1) Only manual electrode holders which are specifically designed for arc welding and cutting, and are of a capacity capable of safely handling the maximum rated current required by the electrodes, shall be used.

(2) Any current-carrying parts passing through the portion of the holder which the arc welder or cutter grips in his hand, and the outer surfaces of the jaws of the holder, shall be fully insulated against the maximum voltage encountered to ground. 2 citations

(b) Welding cables and connectors. Open (b) 26 citations

(1) All arc welding and cutting cables shall be of the completely insulated, flexible type, capable of handling the maximum current requirements of the work in progress, taking into account the duty cycle under which the arc welder or cutter is working. 4 citations

(2) Only cable free from repair or splices for a minimum distance of 10 feet from the cable end to which the electrode holder is connected shall be used, except that cables with standard insulated connectors or with splices whose insulating quality is equal to that of the cable are permitted. Open (b)(2) 8 citations

(3) When it becomes necessary to connect or splice lengths of cable one to another, substantial insulated connectors of a capacity at least equivalent to that of the cable shall be used. If connections are effected by means of cable lugs, they shall be securely fastened together to give good electrical contact, and the exposed metal parts of the lugs shall be completely insulated. Open (b)(3)

(4) Cables in need of repair shall not be used. When a cable, other than the cable lead referred to in paragraph (b)(2) of this section, becomes worn to the extent of exposing bare conductors, the portion thus exposed shall be protected by means of rubber and friction tape or other equivalent insulation. Open (b)(4) 14 citations

(c) Ground returns and machine grounding. Open (c) 2 citations

(1) A ground return cable shall have a safe current carrying capacity equal to or exceeding the specified maximum output capacity of the arc welding or cutting unit which it services. When a single ground return cable services more than one unit, its safe current-carrying capacity shall equal or exceed the total specified maximum output capacities of all the units which it services.

(2) Pipelines containing gases or flammable liquids, or conduits containing electrical circuits, shall not be used as a ground return. For welding on natural gas pipelines, the technical portions of regulations issued by the Department of Transportation, Office of Pipeline Safety, 49 CFR part 192, Minimum Federal Safety Standards for Gas Pipelines, shall apply.

(3) When a structure or pipeline is employed as a ground return circuit, it shall be determined that the required electrical contact exists at all joints. The generation of an arc, sparks, or heat at any point shall cause rejection of the structures as a ground circuit.

(4) When a structure or pipeline is continuously employed as a ground return circuit, all joints shall be bonded, and periodic inspections shall be conducted to ensure that no condition of electrolysis or fire hazard exists by virtue of such use.

(5) The frames of all arc welding and cutting machines shall be grounded either through a third wire in the cable containing the circuit conductor or through a separate wire which is grounded at the source of the current. Grounding circuits, other than by means of the structure, shall be checked to ensure that the circuit between the ground and the grounded power conductor has resistance low enough to permit sufficient current to flow to cause the fuse or circuit breaker to interrupt the current.

(6) All ground connections shall be inspected to ensure that they are mechanically strong and electrically adequate for the required current. Open (c)(6) 2 citations

(d) Operating instructions. Employers shall instruct employees in the safe means of arc welding and cutting as follows: Open (d)

(1) When electrode holders are to be left unattended, the electrodes shall be removed and the holders shall be so placed or protected that they cannot make electrical contact with employees or conducting objects. Open (d)(1)

(2) Hot electrode holders shall not be dipped in water; to do so may expose the arc welder or cutter to electric shock.

(3) When the arc welder or cutter has occasion to leave his work or to stop work for any appreciable length of time, or when the arc welding or cutting machine is to be moved, the power supply switch to the equipment shall be opened.

(4) Any faulty or defective equipment shall be reported to the supervisor.

(5) See § 1926.406(c) for additional requirements.

(e) Shielding. Whenever practicable, all arc welding and cutting operations shall be shielded by noncombustible or flameproof screens which will protect employees and other persons working in the vicinity from the direct rays of the arc. 2 citations

[44 FR 8577, Feb. 9, 1979; 44 FR 20940, Apr. 6, 1979, as amended at 51 FR 25318, July 11, 1986]

Source: eCFR, text current as of 2026-10-15.

See every company cited for this rule.

Export the list: 28 inspections cited 1926.351 in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Injuries linked to this rule

1 death is linked to inspections where OSHA cited 1926.351.

Employee is electrocuted while using stud welder
2024-05-08 · Fatal · PHILADELPHIA, PA

At 12:11 p.m. on May 8, 2024, Employee #1 was installing insulation to ductwork while working on a ladder and using a stud welder. The employee received an electrical shock while using the stud welder, causing him to fall off the ladderto the ground. Emergency…

Where and how often it was cited

YearCitations
20232
202411
202512
20267

Top states: VA (6), MD (6), NV (4), AK (4), TX (3)

Largest penalties

EmployerLocationPenalty for this rule
DELTABJDS, INC.PHILADELPHIA, PA$11,292
RC FABRICATORS, INC.DOVER AFB, DE$8,193
ALLIED TANK & CONSTRUCTION LLCPLAINVIEW, NE$4,850
JNBA CONSTRUCTION CONSULTINGFREDERIKSTED, VI$4,194
H.S. WILLIAMS COMPANY, INC.CHILHOWIE, VA$3,355

Free toolbox talk

A 5-minute crew talk on 1926.351, plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1926.351.

Most-cited parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What electrode holders can be used?

Only manual electrode holders specifically designed for arc welding and cutting and capable of safely handling the maximum rated current of the electrodes.

Can welding cable have splices near the holder?

Not within 10 feet of the end connected to the electrode holder, except standard insulated connectors or splices with insulating quality equal to the cable.

Can a damaged cable be used?

Cables in need of repair shall not be used.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba