29 CFR 1926 · Construction · Subpart K

1926.403(i)(2)(i): Ways to Guard Live Parts at 50 Volts or More

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 20, 2026 3 min read

In plain words:

Employers must guard live parts of electric equipment operating at 50 volts or more against accidental contact with cabinets or other enclosures, or by placing them in a room or vault for qualified persons only, behind partitions or screens, on an elevated balcony or platform, or 8 feet (2.44 m) or more above the floor, arranged to keep unqualified persons out.

Key takeaways

  • 1926.403(i)(2)(i) is part of OSHA's construction standards (29 CFR Part 1926, Subpart K).
  • OSHA cited it 92 times in the last 3 years, in 91 inspections, with $218,587 in current penalties.
  • Most citations: NY (20), MD (16), VA (16).
  • Related part: 1926.403(i) 600 Volts, nominal, or less (100 citations).
  • Free 5-minute toolbox talk for your crew below.
92citations, 3 years
$218,587current penalties
91inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1926.403(i)(2)(i) is one requirement inside 1926.403 General requirements, an OSHA construction standard (Part 1926, Subpart K). It includes 4 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means: 92 citations

(A) By location in a room, vault, or similar enclosure that is accessible only to qualified persons. 1 citations

(B) By partitions or screens so arranged that only qualified persons will have access to the space within reach of the live parts. Any openings in such partitions or screens shall be so sized and located that persons are not likely to come into accidental contact with the live parts or to bring conducting objects into contact with them. 2 citations

(C) By location on a balcony, gallery, or platform so elevated and arranged as to exclude unqualified persons.

(D) By elevation of 8 feet (2.44 m) or more above the floor or other working surface and so installed as to exclude unqualified persons. 5 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1926.403.

Where and how often it was cited

YearCitations
20238
202436
202527
202621

Top states: NY (20), MD (16), VA (16), IN (8), PR (6)

Largest penalties

EmployerLocationPenalty for this rule
BENSON'S OLD HOME KITCHENS BAKERY, LLCBOGART, GA$11,823
LC CONSTRUCTION DELAWARE INC.CAMDEN, DE$8,873
BEL-CON CONSTRUCTION SERVICES, INCEDISON, NJ$7,260
EXCELLENT INTERIOR INC.BROOKLYN, NY$7,098
EJ ELECTRIC, INC.PHILADELPHIA, PA$7,094

Free toolbox talk

A 5-minute crew talk on 1926.403(i)(2)(i), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What voltage triggers this rule?

Live parts of electric equipment operating at 50 volts or more.

What height counts as guarding by elevation?

8 feet (2.44 m) or more above the floor or other working surface, installed to exclude unqualified persons.

What if partitions or screens are used?

Openings must be sized and located so persons are not likely to contact live parts or bring conducting objects into contact with them.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba