29 CFR 1926 · Construction · Subpart K

1926.405(b)(2): Covers on Electrical Boxes

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 20, 2026 3 min read

In plain words:

On construction sites, all pull boxes, junction boxes and fittings must have covers, and metal covers must be grounded. In energized installations each outlet box needs a cover, faceplate or fixture canopy. Outlet box covers with holes for flexible cord pendants must have bushings made for the purpose or smooth, well-rounded surfaces.

Key takeaways

  • 1926.405(b)(2) is part of OSHA's construction standards (29 CFR Part 1926, Subpart K).
  • OSHA cited it 168 times in the last 3 years, in 168 inspections, with $232,601 in current penalties.
  • Most citations: MD (25), VA (20), IN (16).
  • Related part: 1926.405(b) Cabinets, boxes, and fittings (233 citations).
  • Free 5-minute toolbox talk for your crew below.
168citations, 3 years
$232,601current penalties
168inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1926.405(b)(2) ("Covers and canopies") is one requirement inside 1926.405 Wiring methods, components, and equipment for general use, an OSHA construction standard (Part 1926, Subpart K). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(2) Covers and canopies. All pull boxes, junction boxes, and fittings shall be provided with covers. If metal covers are used, they shall be grounded. In energized installations each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear. 168 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1926.405.

Where and how often it was cited

YearCitations
20239
202465
202565
202629

Top states: MD (25), VA (20), IN (16), NY (12), PR (11)

Largest penalties

EmployerLocationPenalty for this rule
THE OSCAR W. LARSON COMPANYGROVE CITY, OH$16,550
EUGENIO LARALAKESIDE MARBLEHEAD, OH$11,292
DIVERZIFY PRO, LLCCHICAGO, IL$10,000
DOBCO, INC.DOVER AFB, DE$8,511
PARAMOUNT BUILDERS, LIMITEDPAGO PAGO, AS$7,022

Free toolbox talk

A 5-minute crew talk on 1926.405(b)(2), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Do junction boxes need covers?

Yes. All pull boxes, junction boxes and fittings shall be provided with covers.

Must metal covers be grounded?

Yes. If metal covers are used, they shall be grounded.

What about cords passing through cover holes?

The holes need bushings designed for the purpose or smooth, well-rounded surfaces.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.