29 CFR 1926 · Construction · Subpart L

1926.451(b): Scaffold platform planking and width

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 19, 2026 7 min read

In plain words:

Each scaffold working platform must be fully planked or decked between the front uprights and the guardrail supports, with no more than 1 inch between planks or between the platform and the uprights unless a wider gap is shown to be necessary (and then no more than 9 1/2 inches). Full planking is not required on platforms used only as walkways or only by erectors and dismantlers. Platforms and walkways must generally be at least 18 inches wide, with exceptions for certain scaffold types.

Key takeaways

  • 1926.451(b) is part of OSHA's construction standards (29 CFR Part 1926, Subpart L).
  • OSHA cited it 1,518 times in the last 3 years, in 1,325 inspections, with $4,859,098 in current penalties.
  • 17 deaths are linked to inspections that cited this rule.
  • Most citations: TX (156), FL (118), NC (103).
  • Related part: 1926.451(b)(1) (870 citations).
  • Free 5-minute toolbox talk for your crew below.
1,518citations, 3 years
$4,859,098current penalties
1,325inspections
17linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1926.451(b) ("Scaffold platform construction") is one requirement inside 1926.451 General requirements, an OSHA construction standard (Part 1926, Subpart L). It includes 19 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(b) Scaffold platform construction. 1,518 citations

(1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows: Open (b)(1) 870 citations

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform). Open (b)(1)(i) 168 citations

(ii) Where the employer makes the demonstration provided for in paragraph (b)(1)(i) of this section, the platform shall be planked or decked as fully as possible and the remaining open space between the platform and the uprights shall not exceed 91⁄2 inches (24.1 cm). Open (b)(1)(ii) 14 citations

Exception to paragraph (b)(1): The requirement in paragraph (b)(1) to provide full planking or decking does not apply to platforms used solely as walkways or solely by employees performing scaffold erection or dismantling. In these situations, only the planking that the employer establishes is necessary to provide safe working conditions is required.

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide. Open (b)(2) 332 citations

(i) Each ladder jack scaffold, top plate bracket scaffold, roof bracket scaffold, and pump jack scaffold shall be at least 12 inches (30 cm) wide. There is no minimum width requirement for boatswains' chairs. Open (b)(2)(i) 11 citations

Pursuant to an administrative stay effective November 29, 1996 and published in the Federal Register on November 25, 1996, the requirement in paragraph (b)(2)(i) that roof bracket scaffolds be at least 12 inches wide is stayed until November 25, 1997 or until rulemaking regarding the minimum width of roof bracket scaffolds has been completed, whichever is later.

(ii) Where scaffolds must be used in areas that the employer can demonstrate are so narrow that platforms and walkways cannot be at least 18 inches (46 cm) wide, such platforms and walkways shall be as wide as feasible, and employees on those platforms and walkways shall be protected from fall hazards by the use of guardrails and/or personal fall arrest systems. Open (b)(2)(ii) 7 citations

(3) Except as provided in paragraphs (b)(3) (i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling. Open (b)(3) 58 citations

(i) The maximum distance from the face for outrigger scaffolds shall be 3 inches (8 cm); Open (b)(3)(i) 1 citations

(ii) The maximum distance from the face for plastering and lathing operations shall be 18 inches (46 cm). Open (b)(3)(ii) 1 citations

(4) Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, shall extend over the centerline of its support at least 6 inches (15 cm). Open (b)(4) 49 citations

(5) Open (b)(5) 118 citations

(i) Each end of a platform 10 feet or less in length shall not extend over its support more than 12 inches (30 cm) unless the platform is designed and installed so that the cantilevered portion of the platform is able to support employees and/or materials without tipping, or has guardrails which block employee access to the cantilevered end. Open (b)(5)(i) 21 citations

(ii) Each platform greater than 10 feet in length shall not extend over its support more than 18 inches (46 cm), unless it is designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end. Open (b)(5)(ii) 97 citations

(6) On scaffolds where scaffold planks are abutted to create a long platform, each abutted end shall rest on a separate support surface. This provision does not preclude the use of common support members, such as “T” sections, to support abutting planks, or hook on platforms designed to rest on common supports. 4 citations

(7) On scaffolds where platforms are overlapped to create a long platform, the overlap shall occur only over supports, and shall not be less than 12 inches (30 cm) unless the platforms are nailed together or otherwise restrained to prevent movement. Open (b)(7) 51 citations

(8) At all points of a scaffold where the platform changes direction, such as turning a corner, any platform that rests on a bearer at an angle other than a right angle shall be laid first, and platforms which rest at right angles over the same bearer shall be laid second, on top of the first platform. Open (b)(8) 9 citations

(9) Wood platforms shall not be covered with opaque finishes, except that platform edges may be covered or marked for identification. Platforms may be coated periodically with wood preservatives, fire-retardant finishes, and slip-resistant finishes; however, the coating may not obscure the top or bottom wood surfaces. Open (b)(9) 2 citations

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound. Open (b)(10) 25 citations

(11) Scaffold components made of dissimilar metals shall not be used together unless a competent person has determined that galvanic action will not reduce the strength of any component to a level below that required by paragraph (a)(1) of this section.

Source: eCFR, text current as of 2026-10-15. Read all of 1926.451.

Injuries linked to this rule

17 deaths are linked to inspections where OSHA cited 1926.451(b).

Employee electrocuted removing gutter
2025-03-04 · Fatal · FALL RIVER, MA

Employee was removing a gutter from a residential structure working from a pump-jack scaffold system erected 4.5 feet from a 79 kilovolt primary power line. The gutter contacted the power line and the employee was electrocuted.

See all 17 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
2023129
2024486
2025569
2026334

Top states: TX (156), FL (118), NC (103), NY (95), VA (92)

Largest penalties

EmployerLocationPenalty for this rule
THOMAS BUILDERS OF VIRGINIA, INC.DALEVILLE, VA$307,480
THOMAS BUILDERS OF VIRGINIA, INC.ROANOKE, VA$130,000
JOSE CALLEPHILADELPHIA, PA$82,757
FINCANTIERI MARINE GROUP, LLCSTURGEON BAY, WI$59,115
JOSE CALLEHATBORO, PA$39,723

Free toolbox talk

A 5-minute crew talk on 1926.451(b), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How big can the gap between scaffold planks be?

No more than 1 inch, unless the employer can show a wider space is necessary; then the platform is planked as fully as possible and the open space to the uprights may not exceed 9 1/2 inches.

How wide must a scaffold platform be?

At least 18 inches, except for the scaffold types listed in paragraphs (b)(2)(i) and (ii).

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba