1926.651(g)(1): Testing Excavation Atmospheres

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 20, 2026 4 min read

In plain words:

Where oxygen deficiency (less than 19.5 percent oxygen) or a hazardous atmosphere exists or could reasonably be expected, employers must test the air before employees enter excavations greater than 4 feet (1.22 m) deep. Employers must protect workers with respiratory protection or ventilation, prevent exposure to flammable gas in excess of 20 percent of the lower flammable limit, and retest as often as needed when controls are used.

Key takeaways

  • 1926.651(g)(1) is part of OSHA's construction standards (29 CFR Part 1926, Subpart P).
  • OSHA cited it 16 times in the last 3 years, in 15 inspections, with $38,807 in current penalties.
  • Most citations: PA (3), AR (2), AZ (2).
  • Related part: 1926.651(g) Hazardous atmospheres (19 citations).
  • Free 5-minute toolbox talk for your crew below.
16citations, 3 years
$38,807current penalties
15inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1926.651(g)(1) ("Testing and controls") is one requirement inside 1926.651 Specific excavation requirements, an OSHA construction standard (Part 1926, Subpart P). It includes 4 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(1) Testing and controls. In addition to the requirements set forth in subparts D and E of this part (29 CFR 1926.50-1926.107) to prevent exposure to harmful levels of atmospheric contaminants and to assure acceptable atmospheric conditions, the following requirements shall apply: 16 citations

(i) Where oxygen deficiency (atmospheres containing less than 19.5 percent oxygen) or a hazardous atmosphere exists or could reasonably be expected to exist, such as in excavations in landfill areas or excavations in areas where hazardous substances are stored nearby, the atmospheres in the excavation shall be tested before employees enter excavations greater than 4 feet (1.22 m) in depth. Open (g)(1)(i) 13 citations

(ii) Adequate precautions shall be taken to prevent employee exposure to atmospheres containing less than 19.5 percent oxygen and other hazardous atmospheres. These precautions include providing proper respiratory protection or ventilation in accordance with subparts D and E of this part respectively. 2 citations

(iii) Adequate precaution shall be taken such as providing ventilation, to prevent employee exposure to an atmosphere containing a concentration of a flammable gas in excess of 20 percent of the lower flammable limit of the gas. Open (g)(1)(iii)

(iv) When controls are used that are intended to reduce the level of atmospheric contaminants to acceptable levels, testing shall be conducted as often as necessary to ensure that the atmosphere remains safe. 1 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1926.651.

Where and how often it was cited

YearCitations
20248
20256
20262

Top states: PA (3), AR (2), AZ (2), TX (2), NJ (2)

Largest penalties

EmployerLocationPenalty for this rule
159103 - S. J. LOUIS CONSTRUCTION, INC.ROXBORO, NC$9,930
159654 - UNITED OF CAROLINAS, INC.CHARLOTTE, NC$4,965
HORSESHOE CONSTRUCTION, INC.ANDREWS, TX$4,840
LUIS ROLDANJONESBORO, AR$4,839
TRETO CONSTRUCTION, LLCCASPER, WY$3,457

Free toolbox talk

A 5-minute crew talk on 1926.651(g)(1), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

When must the air in an excavation be tested?

Before employees enter excavations greater than 4 feet deep where oxygen deficiency or a hazardous atmosphere exists or could reasonably be expected to exist.

What counts as oxygen deficient?

Atmospheres containing less than 19.5 percent oxygen.

What is the flammable gas limit?

Precautions must prevent exposure to flammable gas in excess of 20 percent of the lower flammable limit.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba