1910.147(c)(4)(ii)(A): Lockout Procedure Statement of Intended Use
Each written energy control procedure must include a specific statement of the intended use of the procedure.
Key takeaways
- 1910.147(c)(4)(ii)(A) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart J).
- OSHA cited it 36 times in the last 3 years, in 35 inspections, with $202,598 in current penalties.
- 2 deaths are linked to inspections that cited this rule.
- Most citations: IL (8), OH (5), AL (4).
- Related part: 1910.147(c) General (11,187 citations).
- Free 5-minute toolbox talk for your crew below.
In this article
What this rule covers
29 CFR 1910.147(c)(4)(ii)(A) is one requirement inside 1910.147 The control of hazardous energy (lockout/tagout), an OSHA general industry standard (Part 1910, Subpart J). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.
Official text
(A) A specific statement of the intended use of the procedure; 36 citations
Source: eCFR, text current as of 2026-10-15. Read all of 1910.147.
Injuries linked to this rule
2 deaths are linked to inspections where OSHA cited 1910.147(c)(4)(ii)(A).
On April 9, 2024, an employee was cleaning under a machine that slices veneer. The employee's elbow or torso pressed a pedal which actuated the machine, and hewas pinned between the machine and the floor. The employee was initially hospitalized after the incident on April…
Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).
Unlock with Purple BeltWhere and how often it was cited
| Year | Citations |
|---|---|
| 2023 | 1 |
| 2024 | 16 |
| 2025 | 11 |
| 2026 | 8 |
Top states: IL (8), OH (5), AL (4), WI (4), KY (2)
Largest penalties
| Employer | Location | Penalty for this rule |
|---|---|---|
| CASE FARMS PROCESSING, INC. | WINESBURG, OH | $33,100 |
| C.W. ROBERTS CONTRACTING, INC. | WILDWOOD, FL | $16,550 |
| CULLMAN CASTING CORPORATION | CULLMAN, AL | $13,437 |
| ERNEST MAIER, INC. | MILLSBORO, DE | $13,260 |
| SEATEX, LLC | ROSENBERG, TX | $12,000 |
Free toolbox talk
A 5-minute crew talk on 1910.147(c)(4)(ii)(A), plus alerts when this rule changes. Free.
OSHA interpretation letters
None exist. OSHA has not published a letter of interpretation for 1910.147(c)(4)(ii)(A).
Related parts of this rule
- 1910.147(c) General 11,187 citations
- 1910.147(c)(4) Energy control procedure 4,087 citations
- 1910.147(c)(4)(i) 2,952 citations
- 1910.147(c)(7) Training and communication 2,758 citations
- 1910.147(c)(6) Periodic inspection 2,446 citations
- 1910.147(c)(7)(i) 2,347 citations
- 1910.147(c)(6)(i) 2,024 citations
- 1910.147(c)(1) Energy control program 1,454 citations
- 1910.147(c)(4)(ii) 1,131 citations
- 1910.147(c)(7)(i)(A) 938 citations
- 1910.147(c)(6)(ii) 408 citations
- 1910.147(c)(5) Protective materials and hardware 350 citations
Get your crew competent
Trainers on Black Belt Safety: Marc Harvey, Dana Reyes
Trainers and suppliers: feature your business on this rule for $25/month.
Frequently asked questions
What must an energy control procedure start with?
A specific statement of the intended use of the procedure.
Is a general statement enough?
The rule requires a specific statement of intended use.
Where is this requirement?
1910.147(c)(4)(ii)(A), part of the energy control procedure content rules.
About this page
Sources
- 29 CFR 1910.147 (eCFR), text current as of 2026-10-15
- U.S. Department of Labor enforcement data: OSHA inspections, citations and accident records, copied nightly; data as of 2026-10-20