29 CFR 1910 · General Industry · Subpart S

1910.304(b)(4)(ii): Receptacle Ratings on Branch Circuits

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 20, 2026 3 min read

In plain words:

Receptacle outlets must match their branch circuit. A single receptacle on its own branch circuit must be rated at least as high as the circuit. On circuits with two or more outlets, receptacles may not supply more load than Table S-4 allows and must be rated per Table S-5, or, where larger than 50 amperes, not less than the branch-circuit rating.

Key takeaways

  • 1910.304(b)(4)(ii) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart S).
  • OSHA cited it 70 times in the last 3 years, in 70 inspections, with $85,332 in current penalties.
  • Most citations: MN (43), NV (10), CT (8).
  • Related part: 1910.304(b) Branch circuits (279 citations).
  • Free 5-minute toolbox talk for your crew below.
70citations, 3 years
$85,332current penalties
70inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.304(b)(4)(ii) is one requirement inside 1910.304 Wiring design and protection, an OSHA general industry standard (Part 1910, Subpart S). It includes 3 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(ii) Receptacle outlets shall comply with the following provisions: 70 citations

(A) A single receptacle installed on an individual branch circuit shall have an ampere rating of not less than that of the branch circuit;

(B) Where connected to a branch circuit supplying two or more receptacles or outlets, a receptacle may not supply a total cord- and plug-connected load in excess of the maximum specified in Table S-4; and Open (b)(4)(ii)(b) 70 citations

(C) Where connected to a branch circuit supplying two or more receptacles or outlets, receptacle ratings shall conform to the values listed in Table S-5; or, where larger than 50 amperes, the receptacle rating may not be less than the branch-circuit rating. However, receptacles of cord- and plug-connected arc welders may have ampere ratings not less than the minimum branch-circuit conductor ampacity.

Source: eCFR, text current as of 2026-10-15. Read all of 1910.304.

Where and how often it was cited

YearCitations
20234
202432
202521
202613

Top states: MN (43), NV (10), CT (8), WA (6), NC (1)

Largest penalties

EmployerLocationPenalty for this rule
CLASSIC FLOORS & INTERIORS, LLCLAS VEGAS, NV$11,524
IGNITE TEEN TREATMENT LLCLAS VEGAS, NV$10,046
PARKER PLASTICS NEVADA L.L.CNORTH LAS VEGAS, NV$6,454
THE POINT CASINOKINGSTON, WA$5,627
BOGARTS BONE APPETITLAS VEGAS, NV$4,688

Free toolbox talk

A 5-minute crew talk on 1910.304(b)(4)(ii), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.304(b)(4)(ii).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What rating must a single receptacle on its own circuit have?

An ampere rating of not less than that of the branch circuit.

What limits apply on circuits with two or more receptacles?

A receptacle may not supply a total cord- and plug-connected load over the maximum in Table S-4, and ratings must conform to Table S-5.

Is there an exception for arc welder receptacles?

Yes. Receptacles for cord- and plug-connected arc welders may have ampere ratings not less than the minimum branch-circuit conductor ampacity.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba