29 CFR 1910 · General Industry · Subpart S

1910.333(c)(3)(i): Clearances for Unqualified Workers Near Overhead Lines

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 22, 2026 3 min read

In plain words:

Unqualified workers near unguarded, energized overhead lines must keep themselves and any conductive object at least 10 feet away for lines 50kV or below to ground, plus 4 inches for every 10kV over 50kV. This applies when working elevated or on the ground. Objects without an insulating rating for the voltage are considered conductive.

Key takeaways

  • 1910.333(c)(3)(i) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart S).
  • OSHA cited it 46 times in the last 3 years, in 46 inspections, with $229,517 in current penalties.
  • 11 deaths are linked to inspections that cited this rule.
  • Most citations: FL (13), TX (6), NY (4).
  • Related part: 1910.333(c) Working on or near exposed energized parts (200 citations).
  • Free 5-minute toolbox talk for your crew below.
46citations, 3 years
$229,517current penalties
46inspections
11linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.333(c)(3)(i) ("Unqualified persons") is one requirement inside 1910.333 Selection and use of work practices, an OSHA general industry standard (Part 1910, Subpart S). It includes 2 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(i) Unqualified persons. 46 citations

(A) When an unqualified person is working in an elevated position near overhead lines, the location shall be such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the following distances: Open (c)(3)(i)(a) 36 citations

(1) For voltages to ground 50kV or below—10 ft. (305 cm);

(2) For voltages to ground over 50kV—10 ft. (305 cm) plus 4 in. (10 cm) for every 10kV over 50kV.

(B) When an unqualified person is working on the ground in the vicinity of overhead lines, the person may not bring any conductive object closer to unguarded, energized overhead lines than the distances given in paragraph (c)(3)(i)(A) of this section. Open (c)(3)(i)(b) 10 citations

For voltages normally encountered with overhead power lines, objects which do not have an insulating rating for the voltage involved are considered to be conductive.

Source: eCFR, text current as of 2026-10-15. Read all of 1910.333.

Injuries linked to this rule

11 deaths are linked to inspections where OSHA cited 1910.333(c)(3)(i).

Employee dies from electrocution while trimming tree from li
2025-02-06 · Fatal · MAYER, MN

At 9:03 a.m. on February 6, 2025, Employee #1 working for a tree care company was trimming a tree from a self-propelled boom lift. Using a 21-foot aluminum pole saw to clear up the canopy on a residential property, he turned his body causing him…

See all 11 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
20232
202413
202522
20269

Top states: FL (13), TX (6), NY (4), MD (3), NJ (2)

Largest penalties

EmployerLocationPenalty for this rule
108756 - DISCOUNT TREE CARE INCMAYER, MN$25,000
OSMOSE UTILITIES SERVICES, INC.WEST HELENA, AR$21,508
HUNT FOREST PRODUCTS, LLCPOLLOCK, LA$16,550
SERIOUS TREE SERVICES LLCACWORTH, GA$12,104
CESAR GARCIA LANDSCAPING CORP.MIAMI, FL$11,598

Free toolbox talk

A 5-minute crew talk on 1910.333(c)(3)(i), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.333(c)(3)(i).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How close can an unqualified worker get to a 50kV or lower line?

No closer than 10 feet, including the longest conductive object they may contact.

What about lines over 50kV?

10 feet plus 4 inches for every 10kV over 50kV.

Is a wooden ladder or pole considered conductive?

Objects that do not have an insulating rating for the voltage involved are considered conductive.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba