29 CFR 1926 · Construction · Subpart X

1926.1053(b)(17): Removing Defective Fixed Ladders from Service

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 20, 2026 3 min read

In plain words:

Employers must withdraw fixed ladders with structural defects, such as broken or missing rungs, cleats or steps, broken or split rails, or corroded components, from service until repaired. This is satisfied by immediately tagging the ladder "Do Not Use" or similar, marking it so it is readily identified as defective, or blocking it, such as with plywood spanning several rungs.

Key takeaways

  • 1926.1053(b)(17) is part of OSHA's construction standards (29 CFR Part 1926, Subpart X).
  • OSHA cited it 12 times in the last 3 years, in 12 inspections, with $18,878 in current penalties.
  • Most citations: NC (2), UT (1), PA (1).
  • Related part: 1926.1053(b) Use (10,146 citations).
  • Free 5-minute toolbox talk for your crew below.
12citations, 3 years
$18,878current penalties
12inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1926.1053(b)(17) is one requirement inside 1926.1053 Ladders, an OSHA construction standard (Part 1926, Subpart X). It includes 3 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(17) Fixed ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, or corroded components, shall be withdrawn from service until repaired. The requirement to withdraw a defective ladder from service is satisfied if the ladder is either: 12 citations

(i) Immediately tagged with “Do Not Use” or similar language, 2 citations

(ii) Marked in a manner that readily identifies it as defective;

(iii) Or blocked (such as with a plywood attachment that spans several rungs).

Source: eCFR, text current as of 2026-10-15. Read all of 1926.1053.

Where and how often it was cited

YearCitations
20231
20248
20251
20262

Top states: NC (2), UT (1), PA (1), OR (1), CA (1)

Largest penalties

EmployerLocationPenalty for this rule
SOUTHWEST UTILITY SYSTEMS INC.CAPE CORAL, FL$6,453
CARLTON STRUCTURAL SERVICES CORP.ATLANTIC CITY, NJ$4,256
KARCHER ENVIRONMENTAL, INC.MARCH AIR RESERVE BASE, CA$2,784
STEPHEN F. PETERS INCORPORATEDNEW BERLIN, PA$2,765
THE HASKELL COMPANYSALT LAKE CITY, UT$1,750

Free toolbox talk

A 5-minute crew talk on 1926.1053(b)(17), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1926.1053(b)(17).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What defects take a fixed ladder out of service?

Structural defects such as broken or missing rungs, cleats or steps, broken or split rails, or corroded components.

How do I take a fixed ladder out of service?

Immediately tag it "Do Not Use" or similar, mark it so it is clearly defective, or block it, such as with plywood across several rungs.

How long does it stay out of service?

Until it is repaired.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba