29 CFR 1910 · General Industry · Subpart H

1910.107(h)(12): Automatic Fire Protection for Spray Areas

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated November 6, 2026 3 min read

In plain words:

Employers must protect all areas used for spraying, including the inside of spray booths, with automatic sprinklers where that protection is available. Where it is not available, other approved automatic extinguishing equipment must be provided.

Key takeaways

  • 1910.107(h)(12) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart H).
  • OSHA cited it 10 times in the last 3 years, in 10 inspections, with $28,474 in current penalties.
  • Most citations: VA (2), GA (2), TX (1).
  • Related part: 1910.107(h) Fixed electrostatic apparatus (11 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.107(h)(12) ↓

10citations, 3 years
$28,474current penalties
10inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.107(h)(12) ("Fire protection") is one requirement inside 1910.107 Spray finishing using flammable and combustible materials, an OSHA general industry standard (Part 1910, Subpart H). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(12) Fire protection. All areas used for spraying, including the interior of the booth, shall be protected by automatic sprinklers where this protection is available. Where this protection is not available, other approved automatic extinguishing equipment shall be provided. 10 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.107.

See every company cited for this rule.

Export the list: 10 inspections cited 1910.107(h)(12) in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Where and how often it was cited

YearCitations
20242
20255
20263

Top states: VA (2), GA (2), TX (1), MI (1), PR (1)

Largest penalties

EmployerLocationPenalty for this rule
SIGMA CORPORATIONHOUSTON, TX$8,643
CLASSIC COLLISION, LLCDULUTH, GA$7,093
NIKLYN CORPORATIONNORTH HAVEN, CT$4,138
CORT?S INDUSTRIAL ORGANIZATION INCCAGUAS, PR$3,780
PROLINE CUSTOM CABINETRY LLCODUM, GA$2,000

Free toolbox talk

A 5-minute crew talk on 1910.107(h)(12), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.107(h)(12).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Do spray booths need sprinklers?

All areas used for spraying, including the interior of the booth, must be protected by automatic sprinklers where available.

What if sprinklers are not available?

Other approved automatic extinguishing equipment must be provided.

Does this cover the inside of the booth?

Yes. It includes the interior of the booth.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top