29 CFR 1910 · General Industry · Subpart L

1910.158(c): Equipment

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated November 6, 2026 4 min read

Key takeaways

  • 1910.158(c) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart L).
  • OSHA cited it 8 times in the last 3 years, in 8 inspections, with $10,557 in current penalties.
  • Related part: 1910.158(c)(4) Nozzles.
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.158(c) ↓

8citations, 3 years
$10,557current penalties
8inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. About this page

What this rule covers

29 CFR 1910.158(c) ("Equipment") is one requirement inside 1910.158 Standpipe and hose systems, an OSHA general industry standard (Part 1910, Subpart L). It includes 9 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(c) Equipment — 8 citations

(1) Reels and cabinets. Where reels or cabinets are provided to contain fire hose, the employer shall assure that they are designed to facilitate prompt use of the hose valves, the hose, and other equipment at the time of a fire or other emergency. The employer shall assure that the reels and cabinets are conspicuously identified and used only for fire equipment. 3 citations

(2) Hose outlets and connections. 3 citations

(i) The employer shall assure that hose outlets and connections are located high enough above the floor to avoid being obstructed and to be accessible to employees. 3 citations

(ii) The employer shall standardize screw threads or provide appropriate adapters throughout the system and assure that the hose connections are compatible with those used on the supporting fire equipment.

(3) Hose. 2 citations

(i) The employer shall assure that every 11⁄2″ (3.8 cm) or smaller hose outlet used to meet this standard is equipped with hose connected and ready for use. In extremely cold climates where such installation may result in damaged equipment, the hose may be stored in another location provided it is readily available and can be connected when needed. 2 citations

(ii) Standpipe systems installed after January 1, 1981, for use by employees, shall be equipped with lined hose. Unlined hose may remain in use on existing systems. However, after the effective date of this standard, unlined hose which becomes unserviceable shall be replaced with lined hose.

(iii) The employer shall provide hose of such length that friction loss resulting from water flowing through the hose will not decrease the pressure at the nozzle below 30 psi (210 kPa). The dynamic pressure at the nozzle shall be within the range of 30 psi (210 kPa) to 125 psi (860 kPa).

(4) Nozzles. The employer shall assure that standpipe hose is equipped with shut-off type nozzles. Open (c)(4)

Source: eCFR, text current as of 2026-10-15. Read all of 1910.158.

See every company cited for this rule.

Export the list: 8 inspections cited 1910.158(c) in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Where and how often it was cited

Free toolbox talk

A 5-minute crew talk on 1910.158(c), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.158(c).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top