1910.217(b)(13): Control reliability
Key takeaways
- 1910.217(b)(13) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart O).
- OSHA cited it 3 times in the last 3 years, in 3 inspections, with $9,700 in current penalties.
- Related part: 1910.217(b) Mechanical power press guarding and construction, general (93 citations).
- Free 5-minute toolbox talk for your crew below.
In this article
What this rule covers
29 CFR 1910.217(b)(13) ("Control reliability") is one requirement inside 1910.217 Mechanical power presses, an OSHA general industry standard (Part 1910, Subpart O). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.
Official text
(13) Control reliability. When required by paragraph (c)(5) of this section, the control system shall be constructed so that a failure within the system does not prevent the normal stopping action from being applied to the press when required, but does prevent initiation of a successive stroke until the failure is corrected. The failure shall be detectable by a simple test, or indicated by the control system. This requirement does not apply to those elements of the control system which have no effect on the protection against point of operation injuries. 3 citations
Source: eCFR, text current as of 2026-10-15. Read all of 1910.217.
Where and how often it was cited
Free toolbox talk
A 5-minute crew talk on 1910.217(b)(13), plus alerts when this rule changes. Free.
OSHA interpretation letters
Related parts of this rule
- 1910.217(b) Mechanical power press guarding and construction, general 93 citations
- 1910.217(b)(4) Foot pedals (treadle) 39 citations
- 1910.217(b)(4)(i) 30 citations
- 1910.217(b)(7) Machines using part revolution clutches 29 citations
- 1910.217(b)(7)(iii) 14 citations
- 1910.217(b)(7)(v) 10 citations
- 1910.217(b)(3) Machines using full revolution positive clutches 4 citations
- 1910.217(b)(3)(ii) 1 citations
- 1910.217(b)(1) Hazards to personnel associated with broken or falling machine components 1 citations
- 1910.217(b)(4)(iii)
Get your crew competent
Trainers on Black Belt Safety: Marc Harvey, Dana Reyes
Trainers and suppliers: feature your business on this rule for $25/month.
About this page
Sources
- 29 CFR 1910.217 (eCFR), text current as of 2026-10-15
- U.S. Department of Labor enforcement data: OSHA inspections, citations and accident records, copied nightly; data as of 2026-10-20
3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.