29 CFR 1910 · General Industry · Subpart D

1910.23(d)(2): Clearance Behind Fixed Ladders

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 21, 2026 3 min read

In plain words:

Employers must make sure the minimum perpendicular distance from the centerline of the steps, rungs or grab bars of a fixed ladder to the nearest permanent object behind the ladder is 7 inches (18 cm). Elevator pit ladders need a minimum of 4.5 inches (11 cm).

Key takeaways

  • 1910.23(d)(2) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart D).
  • OSHA cited it 17 times in the last 3 years, in 17 inspections, with $47,035 in current penalties.
  • Most citations: OR (2), MD (2), MN (2).
  • Related part: 1910.23(d) Fixed ladders (114 citations).
  • Free 5-minute toolbox talk for your crew below.
17citations, 3 years
$47,035current penalties
17inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.23(d)(2) is one requirement inside 1910.23 Ladders, an OSHA general industry standard (Part 1910, Subpart D). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(2) The minimum perpendicular distance from the centerline of the steps or rungs, or grab bars, or both, to the nearest permanent object in back of the ladder is 7 inches (18 cm), except for elevator pit ladders, which have a minimum perpendicular distance of 4.5 inches (11 cm); 17 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.23.

Where and how often it was cited

YearCitations
20244
20258
20265

Top states: OR (2), MD (2), MN (2), WI (1), NY (1)

Largest penalties

EmployerLocationPenalty for this rule
TINDALL CORPORATIONSAN ANTONIO, TX$14,187
KALMBACH FEEDS, INC.UPPER SANDUSKY, OH$12,250
TOP AG COOPERATIVE INCNEW DOUGLAS, IL$5,959
R & J GROCERY ENTERPRISES, LLCWEBSTER, WI$5,186
157381 - SUNBRIDGE REGENCY - NORTH CAROLINA, LLCHIGH POINT, NC$4,550

Free toolbox talk

A 5-minute crew talk on 1910.23(d)(2), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.23(d)(2).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How much space is needed behind a fixed ladder?

A minimum perpendicular distance of 7 inches (18 cm) from the centerline of the steps or rungs, or grab bars, to the nearest permanent object behind the ladder.

Is the rule different for elevator pits?

Yes. Elevator pit ladders need a minimum of 4.5 inches (11 cm).

Where is the distance measured from?

From the centerline of the steps or rungs, or grab bars, or both.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top