29 CFR 1910 · General Industry · Subpart D

1910.25: General Industry Stairways

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated November 6, 2026 3 min read

In plain words:

Employers must make sure stairways, including standard, spiral, ship and alternating tread stairs, have handrails, stair rails and guardrails as 1910.28 requires. Stairs need at least 6 feet 8 inches of vertical clearance, uniform risers and treads between landings, landings at least as wide as the stair and 30 inches deep, a platform where doors open onto stairs, and strength for at least five times the normal live load but never less than 1,000 pounds.

Key takeaways

  • 1910.25 is part of OSHA's general industry standards (29 CFR Part 1910, Subpart D).
  • OSHA cited it 290 times in the last 3 years, in 236 inspections, with $484,081 in current penalties.
  • 4 deaths are linked to inspections that cited this rule.
  • Most citations: WI (32), MI (26), NY (23).
  • Most-cited part: 1910.25(b) General requirements (207 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.25 ↓

290citations, 3 years
$484,081current penalties
236inspections
4linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Most-cited parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.25, "Stairways", is an OSHA general industry standard (Part 1910, Subpart D). It has 36 numbered paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

Show the full text of 1910.25 (36 paragraphs)

(a) Application. This section covers all stairways (including standard, spiral, ship, and alternating tread-type stairs), except for articulated stairs (stairs that change pitch due to change in height at the point of attachment) such as those serving floating roof tanks, stairs on scaffolds, stairs designed into machines or equipment, and stairs on self-propelled motorized equipment.

(b) General requirements. The employer must ensure: Open (b) 207 citations

(1) Handrails, stair rail systems, and guardrail systems are provided in accordance with § 1910.28; Open (b)(1) 48 citations

(2) Vertical clearance above any stair tread to any overhead obstruction is at least 6 feet, 8 inches (203 cm), as measured from the leading edge of the tread. Spiral stairs must meet the vertical clearance requirements in paragraph (d)(3) of this section. Open (b)(2) 13 citations

(3) Stairs have uniform riser heights and tread depths between landings; Open (b)(3) 91 citations

(4) Stairway landings and platforms are at least the width of the stair and at least 30 inches (76 cm) in depth, as measured in the direction of travel; Open (b)(4) 12 citations

(5) When a door or a gate opens directly on a stairway, a platform is provided, and the swing of the door or gate does not reduce the platform's effective usable depth to: Open (b)(5) 15 citations

(i) Less than 20 inches (51 cm) for platforms installed before January 17, 2017; and Open (b)(5)(i) 12 citations

(ii) Less than 22 inches (56 cm) for platforms installed on or after January 17, 2017 (see Figure D-7 of this section); 3 citations

(6) Each stair can support at least five times the normal anticipated live load, but never less than a concentrated load of 1,000 pounds (454 kg) applied at any point; 4 citations

(7) Standard stairs are used to provide access from one walking-working surface to another when operations necessitate regular and routine travel between levels, including access to operating platforms for equipment. Winding stairways may be used on tanks and similar round structures when the diameter of the tank or structure is at least 5 feet (1.5 m). Open (b)(7) 19 citations

(8) Spiral, ship, or alternating tread-type stairs are used only when the employer can demonstrate that it is not feasible to provide standard stairs. 5 citations

(9) When paragraph (b)(8) of this section allows the use of spiral, ship, or alternating tread-type stairs, they are installed, used, and maintained in accordance with manufacturer's instructions.

(c) Standard stairs. In addition to paragraph (b) of this section, the employer must ensure standard stairs: Open (c) 77 citations

(1) Are installed at angles between 30 to 50 degrees from the horizontal; Open (c)(1) 3 citations

(2) Have a maximum riser height of 9.5 inches (24 cm); Open (c)(2) 33 citations

(3) Have a minimum tread depth of 9.5 inches (24 cm); and Open (c)(3) 20 citations

(4) Have a minimum width of 22 inches (56 cm) between vertical barriers (see Figure D-8 of this section). Open (c)(4) 12 citations

(5) Exception to paragraphs (c)(2) and (3) of this section. The requirements of paragraphs (c)(2) and (3) do not apply to standard stairs installed prior to January 17, 2017. OSHA will deem those stairs in compliance if they meet the dimension requirements specified in Table D-1 of this section or they use a combination that achieves the angle requirements of paragraph (c)(1) of this section. Open (c)(5) 1 citations

(d) Spiral stairs. In addition to paragraph (b) of this section, the employer must ensure spiral stairs: Open (d) 2 citations

(1) Have a minimum clear width of 26 inches (66 cm); 2 citations

(2) Have a maximum riser height of 9.5 inches (24 cm); Open (d)(2)

(3) Have a minimum headroom above spiral stair treads of at least 6 feet, 6 inches (2 m), measured from the leading edge of the tread;

(4) Have a minimum tread depth of 7.5 inches (19 cm), measured at a point 12 inches (30 cm) from the narrower edge;

(5) Have a uniform tread size;

(e) Ship stairs. In addition to paragraph (b) of this section, the employer must ensure ship stairs (see Figure D-9 of this section): 4 citations

(1) Are installed at a slope of 50 to 70 degrees from the horizontal; 1 citations

(2) Have open risers with a vertical rise between tread surfaces of 6.5 to 12 inches (17 to 30 cm); 1 citations

(3) Have minimum tread depth of 4 inches (10 cm); and

(4) Have a minimum tread width of 18 inches (46 cm). 1 citations

(f) Alternating tread-type stairs. In addition to paragraph (b) of this section, the employer must ensure alternating tread-type stairs:

(1) Have a series of treads installed at a slope of 50 to 70 degrees from the horizontal;

(2) Have a distance between handrails of 17 to 24 inches (51 to 61 cm);

(3) Have a minimum tread depth of 8.5 inches (22 cm); and

(4) Have open risers if the tread depth is less than 9.5 inches (24 cm);

(5) Have a minimum tread width of 7 inches (18 cm), measured at the leading edge of the tread (i.e., nosing).

[81 FR 82981, Nov. 18, 2016, as amended at 84 FR 68795, Dec. 17, 2019]

Source: eCFR, text current as of 2026-10-15.

See every company cited for this rule.

Export the list: 236 inspections cited 1910.25 in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Injuries linked to this rule

4 deaths are linked to inspections where OSHA cited 1910.25.

Employee sustains head trauma in fall from roof, later dies
2024-11-19 · Fatal · LENOIR, NC

On November 19, 2024, an employee working for a specialty mulch manufacturer wascleaning and performing maintenance along with three coworkers. The crew was working on a catwalk on the roof of the plant. The employee stepped off of the catwalk and fell through a skylight…

See all 4 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
20239
202492
2025120
202669

Top states: WI (32), MI (26), NY (23), MD (21), MN (21)

Largest penalties

EmployerLocationPenalty for this rule
GABRIEL CARE, INC.FALL RIVER, MA$33,100
CASE FARMS PROCESSING, INC.WINESBURG, OH$16,550
NEW HORIZONS BAKING COMPANYCOLUMBUS, OH$16,550
CONCRETE TECHNOLOGIES, INC.CUMMING, IA$12,768
IMPACT CONFECTIONS, INC.JANESVILLE, WI$12,413

Free toolbox talk

A 5-minute crew talk on 1910.25, plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.25.

Most-cited parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How much headroom must stairs have?

At least 6 feet, 8 inches (203 cm) from the leading edge of the tread to any overhead obstruction; spiral stairs have their own requirement.

How deep must a stair landing be?

At least 30 inches (76 cm) in the direction of travel, and at least the width of the stair.

How strong must stairs be?

Able to support at least five times the normal anticipated live load, but never less than a concentrated load of 1,000 pounds (454 kg) at any point.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.