1910.268(g): Telecom Climbing Equipment
Telecommunications employers must provide and ensure use of a positioning or personal fall arrest system for work more than 4 feet above the ground, on poles and on towers, with limited exceptions, and inspect climbing equipment before each day's use. Pole climbers may not be used if the gaffs are less than 1 1/4 inches long, must be inspected by a competent person, get a gaff cut-out test at least weekly, and not be worn in listed situations.
Key takeaways
- 1910.268(g) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart R).
- OSHA cited it 10 times in the last 3 years, in 10 inspections, with $44,292 in current penalties.
- 1 death is linked to inspections that cited this rule.
- Most citations: PR (2), WI (2), KY (2).
- Related part: 1910.268(g)(1) General (8 citations).
- Free 5-minute toolbox talk for your crew below.
Get the free 5-minute toolbox talk on 1910.268(g) ↓
In this article
What this rule covers
29 CFR 1910.268(g) ("Personal climbing equipment") is one requirement inside 1910.268 Telecommunications, an OSHA general industry standard (Part 1910, Subpart R). It includes 11 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.
Official text
(g) Personal climbing equipment — 10 citations
(1) General. A positioning system or a personal fall arrest system shall be provided and the employer shall ensure their use when work is performed at positions more than 4 feet (1.2 m) above the ground, on poles, and on towers, except as provided in paragraphs (n)(7) and (8) of this section. These systems shall meet the applicable requirements in subpart I of this part. The employer shall ensure that all climbing equipment is inspected before each day's use to determine that it is in safe working condition. Open (g)(1) 8 citations
(2) Pole climbers. Open (g)(2) 2 citations
(i) Pole climbers may not be used if the gaffs are less than 11⁄4 inches in length as measured on the underside of the gaff. The gaffs of pole climbers shall be covered with safety caps when not being used for their intended use.
(ii) The employer shall ensure that pole climbers are inspected by a competent person for the following conditions: Fractured or cracked gaffs or leg irons, loose or dull gaffs, broken straps or buckles. If any of these conditions exist, the defect shall be corrected before the climbers are used.
(iii) Pole climbers shall be inspected as required in this paragraph (g)(3) before each day's use and a gaff cut-out test performed at least weekly when in use.
(iv) Pole climbers may not be worn when: 2 citations
(A) Working in trees (specifically designed tree climbers shall be used for tree climbing),
(B) Working on ladders,
(C) Working in an aerial lift, 2 citations
(D) Driving a vehicle, nor
(E) Walking on rocky, hard, frozen, brushy or hilly terrain.
Source: eCFR, text current as of 2026-10-15. Read all of 1910.268.
Export the list: 10 inspections cited 1910.268(g) in the last 3 years, with employer, location, penalty and date.
Purple Belt, $59/moInjuries linked to this rule
1 death is linked to inspections where OSHA cited 1910.268(g).
At 6:30 a.m. on February 17, 2025, Employee #1 was ascending a communication tower to assist with the installation of a new telephone communication dish. While climbing, the employee lost footing and fell. Employee #1 sustained fatal injuries.
Where and how often it was cited
| Year | Citations |
|---|---|
| 2024 | 1 |
| 2025 | 2 |
| 2026 | 7 |
Top states: PR (2), WI (2), KY (2), NE (1), LA (1)
Largest penalties
| Employer | Location | Penalty for this rule |
|---|---|---|
| PUERTO RICO TELEPHONE COMPANY INC | PENUELAS, PR | $9,930 |
| ACCURATE PROBUILD SOLUTIONS, LLC | HUMPHREY, NE | $5,485 |
| TRACE WIRELESS, LLC | TRINITY, TX | $4,965 |
| ALVARADO TELECOM, LLC | MENASHA, WI | $4,965 |
| RB TELECOM SERVICES LLC | COTTON VALLEY, LA | $4,500 |
Free toolbox talk
A 5-minute crew talk on 1910.268(g), plus alerts when this rule changes. Free.
OSHA interpretation letters
None exist. OSHA has not published a letter of interpretation for 1910.268(g).
Related parts of this rule
- 1910.268(g)(1) General 8 citations
- 1910.268(g)(2) Pole climbers 2 citations
Get your crew competent
Trainers on Black Belt Safety: Marc Harvey
Trainers and suppliers: feature your business on this rule for $25/month.
Frequently asked questions
When is fall protection required?
When work is performed more than 4 feet above the ground, on poles and on towers, except as provided in (n)(7) and (8).
How often must climbing equipment be inspected?
Before each day's use.
When can pole climbers not be worn?
In trees, on ladders, in aerial lifts, driving, or walking on rocky, hard, frozen, brushy or hilly terrain.
About this page
Sources
- 29 CFR 1910.268 (eCFR), text current as of 2026-10-15
- U.S. Department of Labor enforcement data: OSHA inspections, citations and accident records, copied nightly; data as of 2026-11-17
3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.