29 CFR 1926 · Construction · Subpart Z

1926.1153(c)(2): Silica Table 1 Control Measures

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 19, 2026 3 min read

In plain words:

When using the Table 1 control measures for silica, employers must provide exhaust as needed indoors or in enclosed areas to minimize visible dust buildup, apply water at flow rates enough to minimize visible dust for wet methods, and keep any enclosed cab or booth clean, sealed, under positive pressure with filtered fresh air, and equipped with heating and cooling.

Key takeaways

  • 1926.1153(c)(2) is part of OSHA's construction standards (29 CFR Part 1926, Subpart Z).
  • OSHA cited it 17 times in the last 3 years, in 16 inspections, with $36,603 in current penalties.
  • Most citations: NJ (5), WY (2), AK (1).
  • Related part: 1926.1153(c) Specified exposure control methods (932 citations).
  • Free 5-minute toolbox talk for your crew below.
17citations, 3 years
$36,603current penalties
16inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1926.1153(c)(2) is one requirement inside 1926.1153 Respirable crystalline silica, an OSHA construction standard (Part 1926, Subpart Z). It includes 9 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(2) When implementing the control measures specified in Table 1, each employer shall: 17 citations

(i) For tasks performed indoors or in enclosed areas, provide a means of exhaust as needed to minimize the accumulation of visible airborne dust; 3 citations

(ii) For tasks performed using wet methods, apply water at flow rates sufficient to minimize release of visible dust; Open (c)(2)(ii) 13 citations

(iii) For measures implemented that include an enclosed cab or booth, ensure that the enclosed cab or booth: 1 citations

(A) Is maintained as free as practicable from settled dust;

(B) Has door seals and closing mechanisms that work properly;

(C) Has gaskets and seals that are in good condition and working properly;

(D) Is under positive pressure maintained through continuous delivery of fresh air;

(E) Has intake air that is filtered through a filter that is 95% efficient in the 0.3-10.0 µm range (e.g., MERV-16 or better); and

(F) Has heating and cooling capabilities.

Source: eCFR, text current as of 2026-10-15. Read all of 1926.1153.

Where and how often it was cited

YearCitations
20232
20242
202510
20263

Top states: NJ (5), WY (2), AK (1), IL (1), DE (1)

Largest penalties

EmployerLocationPenalty for this rule
F&G HOME IMPROVEMENT LLCLIVINGSTON, NJ$5,462
FG1 HOME IMPROVEMENT LLCLIVINGSTON, NJ$4,965
STONE HEDGE BUILDERS LLCENGLEWOOD, NJ$4,965
PEREZ LANDSCAPING AND HARDSCAPING LLCDOVER, DE$4,148
LA MOUNTAIN BROTHERS, INC.PLYMOUTH, MA$4,000

Free toolbox talk

A 5-minute crew talk on 1926.1153(c)(2), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1926.1153(c)(2).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What must be done when silica tasks are indoors?

Provide a means of exhaust as needed to minimize the accumulation of visible airborne dust.

How much water is needed for wet methods?

Water must be applied at flow rates sufficient to minimize release of visible dust.

What filter is required for an enclosed cab?

Intake air must be filtered through a filter that is 95% efficient in the 0.3-10.0 µm range, such as MERV-16 or better.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top