29 CFR 1926 · Construction · Subpart L

1926.451(e)(5): Scaffold Ramps and Walkways

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 19, 2026 3 min read

In plain words:

Employers must put guardrail systems on scaffold ramps and walkways 6 feet or more above lower levels. Ramps and walkways may not be inclined more than one vertical to three horizontal (20 degrees), and if steeper than one vertical in eight horizontal they must have cleats not more than 14 inches apart, securely fastened to the planks for footing.

Key takeaways

  • 1926.451(e)(5) is part of OSHA's construction standards (29 CFR Part 1926, Subpart L).
  • OSHA cited it 27 times in the last 3 years, in 26 inspections, with $90,404 in current penalties.
  • Most citations: FL (6), PA (3), TX (2).
  • Related part: 1926.451(e) Access (924 citations).
  • Free 5-minute toolbox talk for your crew below.
27citations, 3 years
$90,404current penalties
26inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1926.451(e)(5) is one requirement inside 1926.451 General requirements, an OSHA construction standard (Part 1926, Subpart L). It includes 3 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(5) Ramps and walkways. 27 citations

(i) Ramps and walkways 6 feet (1.8 m) or more above lower levels shall have guardrail systems which comply with subpart M of this part—Fall Protection; Open (e)(5)(i) 24 citations

(ii) No ramp or walkway shall be inclined more than a slope of one (1) vertical to three (3) horizontal (20 degrees above the horizontal). 2 citations

(iii) If the slope of a ramp or a walkway is steeper than one (1) vertical in eight (8) horizontal, the ramp or walkway shall have cleats not more than fourteen (14) inches (35 cm) apart which are securely fastened to the planks to provide footing. 1 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1926.451.

Where and how often it was cited

YearCitations
20231
202413
20258
20265

Top states: FL (6), PA (3), TX (2), GU (2), OK (1)

Largest penalties

EmployerLocationPenalty for this rule
CORE TECH INTERNATIONALTAMUNING, GU$19,359
VALLEY CONCRETE & CONSTRUCTION, INC.TYRINGHAM, MA$11,585
B & M CONCRETE LLCYBOR CITY, FL$8,937
ROCKEFELLER PLUMBING & HEATING INC.FRANKLIN SQUARE, NY$8,276
CAMPOS ENTERPRISES, LLC.PHILADELPHIA, PA$5,958

Free toolbox talk

A 5-minute crew talk on 1926.451(e)(5), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1926.451(e)(5).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

When do scaffold ramps need guardrails?

When they are 6 feet (1.8 m) or more above lower levels.

How steep can a scaffold ramp be?

No more than a slope of one vertical to three horizontal (20 degrees above the horizontal).

When are cleats required?

When the slope is steeper than one vertical in eight horizontal; cleats must be not more than 14 inches apart and securely fastened.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top