In plain words:

Employers must secure pump jack poles to the structure with rigid triangular bracing or equivalent at the bottom, top and other points as needed. When the pump jack must pass a brace already installed, an extra brace must go approximately 4 feet (1.2 m) above it and stay until the pump jack is moved and the original brace is put back.

Key takeaways

  • 1926.452(j)(2) is part of OSHA's construction standards (29 CFR Part 1926, Subpart L).
  • OSHA cited it 269 times in the last 3 years, in 269 inspections, with $509,522 in current penalties.
  • 4 deaths are linked to inspections that cited this rule.
  • Most citations: MD (48), NJ (35), TX (29).
  • Related part: 1926.452(j) Pump jack scaffolds (276 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1926.452(j)(2) ↓

269citations, 3 years
$509,522current penalties
269inspections
4linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1926.452(j)(2) is one requirement inside 1926.452 Additional requirements applicable to specific types of scaffolds, an OSHA construction standard (Part 1926, Subpart L). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(2) Poles shall be secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled. 269 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1926.452.

See every company cited for this rule.

Export the list: 269 inspections cited 1926.452(j)(2) in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Injuries linked to this rule

4 deaths are linked to inspections where OSHA cited 1926.452(j)(2).

Employee electrocuted removing gutter
2025-03-04 · Fatal · FALL RIVER, MA

Employee was removing a gutter from a residential structure working from a pump-jack scaffold system erected 4.5 feet from a 79 kilovolt primary power line. The gutter contacted the power line and the employee was electrocuted.

See all 4 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
202310
202475
2025100
202684

Top states: MD (48), NJ (35), TX (29), MA (29), NC (27)

Largest penalties

EmployerLocationPenalty for this rule
MASSACHUSETTS GENERAL CONTRACTOR SERVICES CORPLOWELL, MA$16,550
EC SIDING, LLC.WOODLYN, PA$15,210
PRATA CONSTRUCTION LLCJERSEY CITY, NJ$11,916
COSTELLO CONSTRUCTION OF MARYLAND, INC.DEWEY BEACH, DE$9,931
EC SIDING, LLC.MIDDLETOWN, DE$9,126

Free toolbox talk

A 5-minute crew talk on 1926.452(j)(2), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1926.452(j)(2).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How must pump jack poles be secured?

By rigid triangular bracing or equivalent at the bottom, top and other points as necessary.

What is required when passing an existing brace?

An additional brace must be installed approximately 4 feet (1.2 m) above the brace to be passed.

When can the extra brace come off?

It stays in place until the pump jack has been moved and the original brace reinstalled.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top