1926.800(h): Hazardous classifications
Key takeaways
- 1926.800(h) is part of OSHA's construction standards (29 CFR Part 1926, Subpart S).
- Related part: 1926.800(h)(2)(iii).
- Free 5-minute toolbox talk for your crew below.
Get the free 5-minute toolbox talk on 1926.800(h) ↓
In this article
What this rule covers
29 CFR 1926.800(h) ("Hazardous classifications") is one requirement inside 1926.800 Underground construction, an OSHA construction standard (Part 1926, Subpart S). It includes 8 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.
Official text
(h) Hazardous classifications —
(1) Potentially gassy operations. Underground construction operations shall be classified as potentially gassy if either:
(i) Air monitoring discloses 10 percent or more of the lower explosive limit for methane or other flammable gases measured at 12 inches (304.8 mm) ±0.25 inch (6.35 mm) from the roof, face, floor or walls in any underground work area for more than a 24-hour period; or
(ii) The history of the geographical area or geological formation indicates that 10 percent or more of the lower explosive limit for methane or other flammable gases is likely to be encountered in such underground operations.
(2) Gassy operations. Underground construction operations shall be classified as gassy if: Open (h)(2)
(i) Air monitoring discloses 10 percent or more of the lower explosive limit for methane or other flammable gases measured at 12 inches (304.8 mm) ±0.25 inch (6.35 mm) from the roof, face, floor or walls in any underground work area for three consecutive days; or
(ii) There has been an ignition of methane or of other flammable gases emanating from the strata that indicates the presence of such gases; or
(iii) The underground construction operation is both connected to an underground work area which is currently classified as gassy and is also subject to a continuous course of air containing the flammable gas concentration. Open (h)(2)(iii)
(3) Declassification to potentially gassy operations. Underground construction gassy operations may be declassified to Potentially Gassy when air monitoring results remain under 10 percent of the lower explosive limit for methane or other flammable gases for three consecutive days.
Source: eCFR, text current as of 2026-10-15. Read all of 1926.800.
Free toolbox talk
A 5-minute crew talk on 1926.800(h), plus alerts when this rule changes. Free.
OSHA interpretation letters
None exist. OSHA has not published a letter of interpretation for 1926.800(h).
Related parts of this rule
Get your crew competent
Trainers on Black Belt Safety: Marc Harvey
Trainers and suppliers: feature your business on this rule for $25/month.
About this page
Sources
- 29 CFR 1926.800 (eCFR), text current as of 2026-10-15
- U.S. Department of Labor enforcement data: OSHA inspections, citations and accident records, copied nightly
3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.