29 CFR 1910 · General Industry · Subpart J

1910.147(d)(4)(ii): Lockout Devices Hold Safe Position

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 20, 2026 3 min read

In plain words:

Employers must make sure lockout devices, where used, are affixed in a manner that will hold energy isolating devices in a "safe" or "off" position.

Key takeaways

  • 1910.147(d)(4)(ii) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart J).
  • OSHA cited it 25 times in the last 3 years, in 25 inspections, with $238,192 in current penalties.
  • Most citations: TN (5), OR (3), WI (3).
  • Related part: 1910.147(d) Application of control (1,334 citations).
  • Free 5-minute toolbox talk for your crew below.
25citations, 3 years
$238,192current penalties
25inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.147(d)(4)(ii) is one requirement inside 1910.147 The control of hazardous energy (lockout/tagout), an OSHA general industry standard (Part 1910, Subpart J). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(ii) Lockout devices, where used, shall be affixed in a manner to that will hold the energy isolating devices in a “safe” or “off” position. 25 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.147.

Where and how often it was cited

YearCitations
20232
202411
20257
20265

Top states: TN (5), OR (3), WI (3), NE (2), PA (2)

Largest penalties

EmployerLocationPenalty for this rule
ZIPS CAR WASH, LLCMILLEDGEVILLE, GA$165,514
ANIMAL COMFORT GROUP, LLCCROCKETT, TX$12,098
BURKE HANDLING SYSTEMS, INC.FOREST, MS$9,103
317737629 - LETICA CORPORATIONWARREN, OR$6,917
KOHLER CO.KOHLER, WI$6,857

Free toolbox talk

A 5-minute crew talk on 1910.147(d)(4)(ii), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.147(d)(4)(ii).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How must lockout devices be applied?

So they hold energy isolating devices in a "safe" or "off" position.

Does this apply to all lockout devices?

It applies to lockout devices wherever they are used.

Why does placement matter?

A lock that does not hold the isolating device off may not prevent startup.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba