29 CFR 1910 · General Industry · Subpart S

1910.305(g)(1)(iv)(E): No Flexible Cords Hidden in Walls, Ceilings or Floors

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 20, 2026 2 min read

In plain words:

Unless specifically permitted, employers must not use flexible cords and cables where they are concealed behind building walls, ceilings or floors.

Key takeaways

  • 1910.305(g)(1)(iv)(E) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart S).
  • OSHA cited it 12 times in the last 3 years, in 12 inspections, with $0 in current penalties.
  • Most citations: VA (5), TN (2), CT (2).
  • Related part: 1910.305(g) Flexible cords and cables (3,738 citations).
  • Free 5-minute toolbox talk for your crew below.
12citations, 3 years
$0current penalties
12inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.305(g)(1)(iv)(E) is one requirement inside 1910.305 Wiring methods, components, and equipment for general use, an OSHA general industry standard (Part 1910, Subpart S). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(E) Where concealed behind building walls, ceilings, or floors; or 12 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.305.

Where and how often it was cited

YearCitations
20231
20241
20258
20262

Top states: VA (5), TN (2), CT (2), MD (1), NC (1)

Largest penalties

EmployerLocationPenalty for this rule
CRAFT MACHINE WORKS INCHAMPTON, VA$0
CUMBERLAND COUNTY BOARD OF EDUCATION - PHOENIX SCHOOLCROSSVILLE, TN$0
CARROLL COUNTY PUBLIC SCHOOLSWESTMINSTER, MD$0
A A GIBBS LUMBER COSTONY CREEK, VA$0
JORDI CONSTRUCTION, LLCSTONY CREEK, VA$0

Free toolbox talk

A 5-minute crew talk on 1910.305(g)(1)(iv)(E), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.305(g)(1)(iv)(E).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Can extension cords be run inside walls?

No. Unless specifically permitted, flexible cords may not be used where concealed behind building walls, ceilings or floors.

Why are hidden cords a problem?

Damage to a hidden cord cannot be seen, so it can overheat or shock someone.

Is a flexible cord a substitute for permanent wiring?

Hiding cords in walls, ceilings or floors is a prohibited use unless specifically permitted.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba