29 CFR 1926 · Construction · Subpart O

1926.600(a)(6): Equipment Clearance From Power Lines

By Black Belt Safety Editorial Team Official text as of octubre 15, 2026 Data updated octubre 20, 2026 5 min read

In plain words:

Employers must keep equipment near power lines at minimum clearances unless lines are deenergized and visibly grounded or separate insulating barriers are up. Clearance is 10 feet for lines rated 50 kV or below and more for higher voltages. A designated observer is needed when clearance is hard to judge, and any overhead wire is treated as energized until confirmed otherwise.

Key takeaways

  • 1926.600(a)(6) is part of OSHA's construction standards (29 CFR Part 1926, Subpart O).
  • OSHA cited it 64 times in the last 3 years, in 45 inspections, with $525,699 in current penalties.
  • 3 deaths are linked to inspections that cited this rule.
  • Most citations: TX (16), MA (6), FL (5).
  • Related part: 1926.600(a) General requirements (111 citations).
  • Free 5-minute toolbox talk for your crew below.
64citations, 3 years
$525,699current penalties
45inspections
3linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1926.600(a)(6) is one requirement inside 1926.600 Equipment, an OSHA construction standard (Part 1926, Subpart O). It includes 10 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(6) All equipment covered by this subpart shall comply with the following requirements when working or being moved in the vicinity of power lines or energized transmitters, except where electrical distribution and transmission lines have been deenergized and visibly grounded at point of work or where insulating barriers, not a part of or an attachment to the equipment or machinery, have been erected to prevent physical contact with the lines: 64 citations

(i) For lines rated 50 kV or below, minimum clearance between the lines and any part of the crane or load shall be 10 feet; Open (a)(6)(i) 37 citations

(ii) For lines rated over 50 kV, minimum clearance between the lines and any part of the crane or load shall be 10 feet plus 0.4 inch for each 1 kV over 50 kV, or twice the length of the line insulator, but never less than 10 feet; 2 citations

(iii) In transit with no load and boom lowered, the equipment clearance shall be a minimum of 4 feet for voltages less than 50 kV, and 10 feet for voltages over 50 kV, up to and including 345 kV, and 16 feet for voltages up to and including 750 kV;

(iv) A person shall be designated to observe clearance of the equipment and give timely warning for all operations where it is difficult for the operator to maintain the desired clearance by visual means; Open (a)(6)(iv) 18 citations

(v) Cage-type boom guards, insulating links, or proximity warning devices may be used on cranes, but the use of such devices shall not alter the requirements of any other regulation of this part even if such device is required by law or regulation;

(vi) Any overhead wire shall be considered to be an energized line unless and until the person owning such line or the electrical utility authorities indicate that it is not an energized line and it has been visibly grounded; 2 citations

(vii) Prior to work near transmitter towers where an electrical charge can be induced in the equipment or materials being handled, the transmitter shall be de-energized or tests shall be made to determine if electrical charge is induced on the crane. The following precautions shall be taken when necessary to dissipate induced voltages: 1 citations

(A) The equipment shall be provided with an electrical ground directly to the upper rotating structure supporting the boom; and 1 citations

(B) Ground jumper cables shall be attached to materials being handled by boom equipment when electrical charge is induced while working near energized transmitters. Crews shall be provided with nonconductive poles having large alligator clips or other similar protection to attach the ground cable to the load.

(C) Combustible and flammable materials shall be removed from the immediate area prior to operations.

Source: eCFR, text current as of 2026-10-15. Read all of 1926.600.

Injuries linked to this rule

3 deaths are linked to inspections where OSHA cited 1926.600(a)(6).

Employee dies after electrocuted, boom contacts power line
2025-01-15 · Fatal · BILOXI, MS

At 8:00 a.m. on January 15, 2025, Employee #1 was working for a concrete pumping service was pouring concrete with a pumping hose. The employee moved thehose boom which contacted a nearby overhead high voltage power line. Employee #1 was fatally injured.

See all 3 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
20232
202416
202522
202624

Top states: TX (16), MA (6), FL (5), VA (5), KY (4)

Largest penalties

EmployerLocationPenalty for this rule
BLACK ROCK CONSTRUCTION MANAGEMENT, LLC.BRUCEVILLE, TX$145,652
A.D. PAOLINI LLCWINTHROP, MA$39,723
WALKER-HILL ENVIRONMENTAL, INC.OAKLAND, MS$28,135
KIOWA LINE BUILDERS INCVANZANT, MO$23,228
CONCRETE PUMP PARTNERS LLCBILOXI, MS$16,550

Free toolbox talk

A 5-minute crew talk on 1926.600(a)(6), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How close can equipment get to a power line rated 50 kV or below?

Minimum clearance between the lines and any part of the crane or load shall be 10 feet.

What clearance applies in transit with no load and boom lowered?

A minimum of 4 feet for voltages less than 50 kV, 10 feet for over 50 kV up to and including 345 kV, and 16 feet up to and including 750 kV.

Should an overhead wire be assumed dead?

No. Any overhead wire is considered energized until the owner or utility says it is not and it has been visibly grounded.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Desplácese hacia arriba