29 CFR 1910 · General Industry · Subpart H

1910.106(d)(3)(ii): Fire Resistance of Flammable Cabinets

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 21, 2026 4 min read

In plain words:

Employers must use flammable storage cabinets built to keep internal temperature to not more than 325 degrees F in a 10-minute fire test, with tight joints and a door that stays closed, labeled "Flammable - Keep Fire Away." The rule lists construction details for metal and wooden cabinets that are deemed compliant.

Key takeaways

  • 1910.106(d)(3)(ii) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart H).
  • OSHA cited it 59 times in the last 3 years, in 59 inspections, with $87,542 in current penalties.
  • Most citations: VA (10), CA (9), MN (6).
  • Related part: 1910.106(d) Container and portable tank storage (357 citations).
  • Free 5-minute toolbox talk for your crew below.
59citations, 3 years
$87,542current penalties
59inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.106(d)(3)(ii) ("Fire resistance") is one requirement inside 1910.106 Flammable liquids, an OSHA general industry standard (Part 1910, Subpart H). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.” 59 citations

(a) Metal cabinets constructed in the following manner shall be deemed to be in compliance. The bottom, top, door, and sides of cabinet shall be at least No. 18 gage sheet iron and double walled with 11⁄2-inch air space. Joints shall be riveted, welded or made tight by some equally effective means. The door shall be provided with a three-point lock, and the door sill shall be raised at least 2 inches above the bottom of the cabinet.

(b) Wooden cabinets constructed in the following manner shall be deemed in compliance. The bottom, sides, and top shall be constructed of an approved grade of plywood at least 1 inch in thickness, which shall not break down or delaminate under fire conditions. All joints shall be rabbetted and shall be fastened in two directions with flathead woodscrews. When more than one door is used, there shall be a rabbetted overlap of not less than 1 inch. Hinges shall be mounted in such a manner as not to lose their holding capacity due to loosening or burning out of the screws when subjected to the fire test.

Source: eCFR, text current as of 2026-10-15. Read all of 1910.106.

Where and how often it was cited

YearCitations
20232
202419
202529
20269

Top states: VA (10), CA (9), MN (6), IL (5), CT (3)

Largest penalties

EmployerLocationPenalty for this rule
SOCORRO, CITY OF, VEHICLE MAINTENANCE DEPARTMENTSOCORRO, NM$10,125
ROCK RIVER LUMBER AND GRAIN CO.STERLING, IL$7,448
THE GOODYEAR TIRE & RUBBER COMPANYDANVILLE, VA$7,025
FONTAINE MODIFICATION CO.DUBLIN, VA$6,797
HOLLAND, L.P.UNIVERSITY PARK, IL$6,500

Free toolbox talk

A 5-minute crew talk on 1910.106(d)(3)(ii), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.106(d)(3)(ii).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What temperature must a cabinet hold during a fire test?

Not more than 325 F internally when subjected to a 10-minute fire test.

What are the wooden cabinet specs?

Approved plywood at least 1 inch thick, rabbetted joints fastened in two directions with flathead woodscrews, and at least a 1 inch rabbetted overlap with more than one door.

What label is required?

Conspicuous lettering reading "Flammable - Keep Fire Away."

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top