29 CFR 1910 · General Industry · Subpart H

1910.107(c)(6): Electrical Wiring In and Near Spray Areas

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 20, 2026 3 min read

In plain words:

Employers must use explosion-proof wiring and equipment approved for Class I, group D locations inside spraying areas where it is not subject to combustible residue deposits, meeting subpart S rules for Class I, Division 1. Wiring, motors and equipment outside but within 20 feet of a spraying area, and not separated by partitions, must not spark in normal operation and must meet Class I, Division 2 rules.

Key takeaways

  • 1910.107(c)(6) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart H).
  • OSHA cited it 91 times in the last 3 years, in 91 inspections, with $123,209 in current penalties.
  • Most citations: MN (17), MI (10), TN (9).
  • Related part: 1910.107(c) Electrical and other sources of ignition (230 citations).
  • Free 5-minute toolbox talk for your crew below.
91citations, 3 years
$123,209current penalties
91inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.107(c)(6) ("Wiring type approved") is one requirement inside 1910.107 Spray finishing using flammable and combustible materials, an OSHA general industry standard (Part 1910, Subpart H). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations. 91 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.107.

Where and how often it was cited

YearCitations
20237
202426
202525
202633

Top states: MN (17), MI (10), TN (9), CT (6), WI (5)

Largest penalties

EmployerLocationPenalty for this rule
GALVION BALLISTICS LTD.NEWPORT, VT$12,025
155973 - LIFTONE LLCGREENSBORO, NC$9,140
PROCESS MANUFACTURING COMPANY, INC.TULSA, OK$9,100
RELEASE BW, INC.EGG HARBOR CITY, NJ$6,000
AQUA TREATMENT SERVICES, INC.MECHANICSBURG, PA$5,748

Free toolbox talk

A 5-minute crew talk on 1910.107(c)(6), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What wiring is required in a spraying area?

Explosion-proof type approved for Class I, group D locations, conforming to subpart S for Class I, Division 1 hazardous locations.

What about equipment near a spray area?

Within 20 feet and not separated by partitions, it must not produce sparks under normal operation and must meet Class I, Division 2 rules.

Does a partition change the rule?

The 20-foot rule applies to equipment not separated from the spraying area by partitions.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top