29 CFR 1910 · General Industry · Subpart H

1910.107(c): Ignition Sources in Spray Finishing Areas

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 20, 2026 5 min read

In plain words:

Employers must control electrical equipment, open flames and other ignition sources in spray finishing areas. No open flame or spark-producing equipment is allowed in a spraying area or within 20 feet of it unless separated by a partition, hot surfaces may not be where combustible residue can build up, electrical equipment is limited where residue collects, and other wiring in spraying areas must be explosion-proof type approved for Class I, group D locations.

Key takeaways

  • 1910.107(c) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart H).
  • OSHA cited it 230 times in the last 3 years, in 175 inspections, with $315,032 in current penalties.
  • Most citations: MI (31), TN (30), MN (27).
  • Related part: 1910.107(c)(6) Wiring type approved (91 citations).
  • Free 5-minute toolbox talk for your crew below.
230citations, 3 years
$315,032current penalties
175inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.107(c) ("Electrical and other sources of ignition") is one requirement inside 1910.107 Spray finishing using flammable and combustible materials, an OSHA general industry standard (Part 1910, Subpart H). It includes 15 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(c) Electrical and other sources of ignition — 230 citations

(1) Conformance. All electrical equipment, open flames and other sources of ignition shall conform to the requirements of this paragraph, except as follows:

(i) Electrostatic apparatus shall conform to the requirements of paragraphs (h) and (i) of this section;

(ii) Drying, curing, and fusion apparatus shall conform to the requirements of paragraph (j) of this section;

(iii) Automobile undercoating spray operations in garages shall conform to the requirements of paragraph (k) of this section;

(iv) Powder-coating equipment shall conform to the requirements of paragraph (l)(1) of this section.

(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition. Open (c)(2) 34 citations

(3) Hot surfaces. Space-heating appliances, steampipes, or hot surfaces shall not be located in a spraying area where deposits of combustible residues may readily accumulate. 9 citations

(4) Wiring conformance. Electrical wiring and equipment shall conform to the provisions of this paragraph and shall otherwise be in accordance with subpart S of this part. 5 citations

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections. Open (c)(5) 56 citations

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations. Open (c)(6) 91 citations

(7) Lamps. Electric lamps outside of, but within twenty (20) feet of any spraying area, and not separated therefrom by a partition, shall be totally enclosed to prevent the falling of hot particles and shall be protected from mechanical injury by suitable guards or by location. Open (c)(7) 14 citations

(8) Portable lamps. Portable electric lamps shall not be used in any spraying area during spraying operations. Portable electric lamps, if used during cleaning or repairing operations, shall be of the type approved for hazardous Class I locations. 9 citations

(9) Grounding. Open (c)(9) 12 citations

(i) All metal parts of spray booths, exhaust ducts, and piping systems conveying flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) or aerated solids shall be properly electrically grounded in an effective and permanent manner. Open (c)(9)(i) 12 citations

(ii) [Reserved]

Source: eCFR, text current as of 2026-10-15. Read all of 1910.107.

Where and how often it was cited

YearCitations
202316
202471
202574
202669

Top states: MI (31), TN (30), MN (27), VA (14), CT (11)

Largest penalties

EmployerLocationPenalty for this rule
ASSA ABLOYEASTON, PA$15,000
WASTEQUIP MANUFACTURING COMPANY, LLCTYLER, TX$14,895
BROKEN ARROW POWDER COATING, INC.BROKEN ARROW, OK$13,000
GALVION BALLISTICS LTD.NEWPORT, VT$12,025
155973 - LIFTONE LLCGREENSBORO, NC$9,140

Free toolbox talk

A 5-minute crew talk on 1910.107(c), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How far must open flames be from a spraying area?

There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.

Can space heaters be in a spraying area?

Not where deposits of combustible residues may readily accumulate.

What wiring is allowed where residue builds up?

Unless specifically approved, only wiring in rigid conduit or in boxes or fittings containing no taps, splices or terminal connections.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top