29 CFR 1910 · General Industry · Subpart H

1910.119(e)(3): What a Process Hazard Analysis Must Cover

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 21, 2026 3 min read

In plain words:

Employers' process hazard analysis must address the process hazards, any previous incident with likely catastrophic potential, engineering and administrative controls and how they relate, and the consequences of control failure. It must also cover facility siting, human factors, and a qualitative evaluation of possible safety and health effects of control failure on employees.

Key takeaways

  • 1910.119(e)(3) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart H).
  • OSHA cited it 77 times in the last 3 years, in 47 inspections, with $731,687 in current penalties.
  • 1 death is linked to inspections that cited this rule.
  • Most citations: OH (15), PA (9), WI (5).
  • Related part: 1910.119(e) Process hazard analysis (165 citations).
  • Free 5-minute toolbox talk for your crew below.
77citations, 3 years
$731,687current penalties
47inspections
1linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.119(e)(3) is one requirement inside 1910.119 Process safety management of highly hazardous chemicals, an OSHA general industry standard (Part 1910, Subpart H). It includes 7 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(3) The process hazard analysis shall address: 77 citations

(i) The hazards of the process; Open (e)(3)(i) 20 citations

(ii) The identification of any previous incident which had a likely potential for catastrophic consequences in the workplace; 2 citations

(iii) Engineering and administrative controls applicable to the hazards and their interrelationships such as appropriate application of detection methodologies to provide early warning of releases. (Acceptable detection methods might include process monitoring and control instrumentation with alarms, and detection hardware such as hydrocarbon sensors.); Open (e)(3)(iii) 14 citations

(iv) Consequences of failure of engineering and administrative controls; Open (e)(3)(iv) 10 citations

(v) Facility siting; Open (e)(3)(v) 10 citations

(vi) Human factors; and Open (e)(3)(vi) 15 citations

(vii) A qualitative evaluation of a range of the possible safety and health effects of failure of controls on employees in the workplace. 4 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.119.

Injuries linked to this rule

1 death is linked to inspections where OSHA cited 1910.119(e)(3).

One employee is killed and two others are injured in explosi
2024-07-03 · Fatal · HAMPTON, AR

At 8:15 a.m. on July 3, 2024, Employee #1, Employee #2, and Employee #3 were inserting smoke composition material into aluminum pyrotechnic vessels when an explosion occurred. Employee #1 was fatally injured. Employee #2 was hospitalized, and Employee #3 sustained non-hospitalized injuries. The incident involved…

Where and how often it was cited

YearCitations
20238
202418
202531
202620

Top states: OH (15), PA (9), WI (5), NC (5), NJ (4)

Largest penalties

EmployerLocationPenalty for this rule
ACCURATE ENERGETIC SYSTEMS, LLCMC EWEN, TN$280,000
AMERICAN NITRILE OPERATIONS, LLC.GROVE CITY, OH$49,650
HORNADY MANUFACTURINGALDA, NE$23,000
VANDEMARK CHEMICAL, INC.LOCKPORT, NY$22,500
THE SHERWIN-WILLIAMS COMPANYGARLAND, TX$19,358

Free toolbox talk

A 5-minute crew talk on 1910.119(e)(3), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

What must a PHA address?

Process hazards, previous incidents with catastrophic potential, controls, consequences of control failure, facility siting, human factors, and possible effects of control failure on employees.

Does a PHA consider past incidents?

Yes. It must identify any previous incident which had a likely potential for catastrophic consequences.

What detection methods are mentioned?

Process monitoring and control instrumentation with alarms, and detection hardware such as hydrocarbon sensors, are given as acceptable examples.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top