1910.134(i): Breathing Air Quality for Supplied-Air Respirators
Employers must give employees using supplied-air respirators and SCBA high-purity breathing gases. Oxygen must meet US Pharmacopoeia requirements, and compressed air must meet at least Grade D, including 19.5-23.5% oxygen, 5 mg/m3 or less condensed hydrocarbons, 10 ppm or less carbon monoxide, 1,000 ppm or less carbon dioxide, and no noticeable odor. Cylinders must be DOT tested, purchased air needs a certificate of analysis, and moisture must not exceed a dew point of -50 F.
Key takeaways
- 1910.134(i) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart I).
- OSHA cited it 149 times in the last 3 years, in 116 inspections, with $236,261 in current penalties.
- 3 deaths are linked to inspections that cited this rule.
- Most citations: IL (38), NJ (13), WI (10).
- Related part: 1910.134(i)(4) (43 citations).
- Free 5-minute toolbox talk for your crew below.
In this article
What this rule covers
29 CFR 1910.134(i) ("Breathing air quality and use") is one requirement inside 1910.134 Respiratory protection, an OSHA general industry standard (Part 1910, Subpart I). It includes 23 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.
Official text
(i) Breathing air quality and use. This paragraph requires the employer to provide employees using atmosphere-supplying respirators (supplied-air and SCBA) with breathing gases of high purity. 149 citations
(1) The employer shall ensure that compressed air, compressed oxygen, liquid air, and liquid oxygen used for respiration accords with the following specifications: Open (i)(1) 34 citations
(i) Compressed and liquid oxygen shall meet the United States Pharmacopoeia requirements for medical or breathing oxygen; and Open (i)(1)(i)
(ii) Compressed breathing air shall meet at least the requirements for Grade D breathing air described in ANSI/Compressed Gas Association Commodity Specification for Air, G-7.1-1989, to include: Open (i)(1)(ii) 31 citations
(A) Oxygen content (v/v) of 19.5-23.5%; Open (i)(1)(ii)(a) 2 citations
(B) Hydrocarbon (condensed) content of 5 milligrams per cubic meter of air or less;
(C) Carbon monoxide (CO) content of 10 ppm or less;
(D) Carbon dioxide content of 1,000 ppm or less; and
(E) Lack of noticeable odor. 1 citations
(2) The employer shall ensure that compressed oxygen is not used in atmosphere-supplying respirators that have previously used compressed air.
(3) The employer shall ensure that oxygen concentrations greater than 23.5% are used only in equipment designed for oxygen service or distribution.
(4) The employer shall ensure that cylinders used to supply breathing air to respirators meet the following requirements: Open (i)(4) 43 citations
(i) Cylinders are tested and maintained as prescribed in the Shipping Container Specification Regulations of the Department of Transportation (49 CFR part 180); Open (i)(4)(i) 18 citations
(ii) Cylinders of purchased breathing air have a certificate of analysis from the supplier that the breathing air meets the requirements for Grade D breathing air; and Open (i)(4)(ii) 3 citations
(iii) The moisture content in the cylinder does not exceed a dew point of −50 °F (−45.6 °C) at 1 atmosphere pressure. Open (i)(4)(iii)
(5) The employer shall ensure that compressors used to supply breathing air to respirators are constructed and situated so as to: Open (i)(5) 34 citations
(i) Prevent entry of contaminated air into the air-supply system; Open (i)(5)(i) 3 citations
(ii) Minimize moisture content so that the dew point at 1 atmosphere pressure is 10 degrees F (5.56 °C) below the ambient temperature; Open (i)(5)(ii)
(iii) Have suitable in-line air-purifying sorbent beds and filters to further ensure breathing air quality. Sorbent beds and filters shall be maintained and replaced or refurbished periodically following the manufacturer's instructions. 6 citations
(iv) Have a tag containing the most recent change date and the signature of the person authorized by the employer to perform the change. The tag shall be maintained at the compressor. Open (i)(5)(iv) 24 citations
(6) For compressors that are not oil-lubricated, the employer shall ensure that carbon monoxide levels in the breathing air do not exceed 10 ppm. 1 citations
(7) For oil-lubricated compressors, the employer shall use a high-temperature or carbon monoxide alarm, or both, to monitor carbon monoxide levels. If only high-temperature alarms are used, the air supply shall be monitored at intervals sufficient to prevent carbon monoxide in the breathing air from exceeding 10 ppm. Open (i)(7) 30 citations
(8) The employer shall ensure that breathing air couplings are incompatible with outlets for nonrespirable worksite air or other gas systems. No asphyxiating substance shall be introduced into breathing air lines. Open (i)(8) 7 citations
(9) The employer shall use only the respirator manufacturer's NIOSH-approved breathing-gas containers, marked and maintained in accordance with the Quality Assurance provisions of the NIOSH approval for the SCBA as issued in accordance with the NIOSH respirator-certification standard at 42 CFR part 84.
Source: eCFR, text current as of 2026-10-15. Read all of 1910.134.
Injuries linked to this rule
3 deaths are linked to inspections where OSHA cited 1910.134(i).
At 11:43 a.m. on February 24, 2025, Employee #1 was spray painting aircraft parts while wearing a supplied air respirator. Nitrogen back flowed into the breathing air system, displacing oxygen and causing the employee to be asphyxiated. Employee #1 was fatally injured.
Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).
Unlock with Purple BeltWhere and how often it was cited
| Year | Citations |
|---|---|
| 2023 | 4 |
| 2024 | 59 |
| 2025 | 50 |
| 2026 | 36 |
Top states: IL (38), NJ (13), WI (10), TX (10), PA (9)
Largest penalties
| Employer | Location | Penalty for this rule |
|---|---|---|
| TEXTRON AVIATION INC | WICHITA, KS | $33,100 |
| HENKELS & MCCOY, INC. | YORK, PA | $16,550 |
| POWER FLAME, INC | PARSONS, KS | $16,385 |
| BALIUS INDUSTRIAL, LLC | AXIS, AL | $15,819 |
| GREENBRIER RAIL SERVICES DBA AMERICAN HYDRAULICS | RED OAK, IA | $14,063 |
Free toolbox talk
A 5-minute crew talk on 1910.134(i), plus alerts when this rule changes. Free.
OSHA interpretation letters
- Clarifications for breathing air quality and use (2023-05-31)
- 1910.134(i) does not apply to portable breathing air compressors. (1999-08-13)
- Using a "generic type" certificate of analysis for Grade D breathing air. (1999-02-05)
- Carbon Monoxide or High Temperature Alarm Requirement for Portable Breathing Air Compressors. (1994-07-05)
- Breathing air: testing and carbon monoxide alarm. (1994-04-25)
- Couplings used in supplied air respirator systems. (1986-04-24)
- Alarm requirements for breathing air compressors;Respirators for paint materials containing TDI or MDI;Full facepiece respirators are required when eye irritation is experienced. (1986-03-03)
- Del-Monox air purifiers are unacceptable for testing carbon monoxide concentration for compressor breathing air. (1981-10-15)
- Cool-view welding helmets must meet Grade D breathing air requirements; Requirements for standard welding helmets. (1981-07-14)
- Respirator air quality standards do not apply where the NRC has jurisdiction (1979-03-06)
Related parts of this rule
- 1910.134(i)(4) 43 citations
- 1910.134(i)(1) 34 citations
- 1910.134(i)(5) 34 citations
- 1910.134(i)(1)(ii) 31 citations
- 1910.134(i)(7) 30 citations
- 1910.134(i)(5)(iv) 24 citations
- 1910.134(i)(4)(i) 18 citations
- 1910.134(i)(8) 7 citations
- 1910.134(i)(4)(ii) 3 citations
- 1910.134(i)(5)(i) 3 citations
- 1910.134(i)(1)(ii)(A) 2 citations
- 1910.134(i)(1)(i)
Get your crew competent
Trainers on Black Belt Safety: Marc Harvey, Dana Reyes
Trainers and suppliers: feature your business on this rule for $25/month.
Frequently asked questions
What grade of breathing air is required?
At least Grade D breathing air under ANSI/CGA G-7.1-1989.
What is the carbon monoxide limit for breathing air?
10 ppm or less.
Can oxygen be used in a respirator that used compressed air?
No. Compressed oxygen must not be used in atmosphere-supplying respirators that previously used compressed air.
About this page
Sources
- 29 CFR 1910.134 (eCFR), text current as of 2026-10-15
- U.S. Department of Labor enforcement data: OSHA inspections, citations and accident records, copied nightly; data as of 2026-10-22
3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.