29 CFR 1910 · General Industry · Subpart L

1910.157(d): Choosing and Placing Fire Extinguishers

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated November 6, 2026 4 min read

In plain words:

Employers must select and distribute portable fire extinguishers based on the classes of expected fires and the hazards. Travel distance must be 75 feet or less for Class A, 50 feet or less for Class B, and 75 feet or less for Class D. Class C follows the Class A or B pattern. Standpipes or hose stations may replace Class A extinguishers under the conditions the rule sets.

Key takeaways

  • 1910.157(d) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart L).
  • OSHA cited it 19 times in the last 3 years, in 19 inspections, with $42,718 in current penalties.
  • Most citations: PR (3), NV (2), DE (1).
  • Related part: 1910.157(d)(1) (7 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.157(d) ↓

19citations, 3 years
$42,718current penalties
19inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.157(d) ("Selection and distribution") is one requirement inside 1910.157 Portable fire extinguishers, an OSHA general industry standard (Part 1910, Subpart L). It includes 6 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(d) Selection and distribution. 19 citations

(1) Portable fire extinguishers shall be provided for employee use and selected and distributed based on the classes of anticipated workplace fires and on the size and degree of hazard which would affect their use. Open (d)(1) 7 citations

(2) The employer shall distribute portable fire extinguishers for use by employees on Class A fires so that the travel distance for employees to any extinguisher is 75 feet (22.9 m) or less. 6 citations

(3) The employer may use uniformly spaced standpipe systems or hose stations connected to a sprinkler system installed for emergency use by employees instead of Class A portable fire extinguishers, provided that such systems meet the respective requirements of § 1910.158 or § 1910.159, that they provide total coverage of the area to be protected, and that employees are trained at least annually in their use. Open (d)(3)

(4) The employer shall distribute portable fire extinguishers for use by employees on Class B fires so that the travel distance from the Class B hazard area to any extinguisher is 50 feet (15.2 m) or less. 5 citations

(5) The employer shall distribute portable fire extinguishers used for Class C hazards on the basis of the appropriate pattern for the existing Class A or Class B hazards.

(6) The employer shall distribute portable fire extinguishers or other containers of Class D extinguishing agent for use by employees so that the travel distance from the combustible metal working area to any extinguishing agent is 75 feet (22.9 m) or less. Portable fire extinguishers for Class D hazards are required in those combustible metal working areas where combustible metal powders, flakes, shavings, or similarly sized products are generated at least once every two weeks. 1 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.157.

See every company cited for this rule.

Export the list: 19 inspections cited 1910.157(d) in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Where and how often it was cited

YearCitations
20247
20256
20266

Top states: PR (3), NV (2), DE (1), SD (1), TX (1)

Largest penalties

EmployerLocationPenalty for this rule
GXO WAREHOUSE COMPANY, INC.NEW CASTLE, DE$12,929
NATIONAL FURNITURE LIQUIDATORSALBUQUERQUE, NM$9,562
DE ESCUELA S.U ENRIQUE DE JES?S BORR?SARECIBO, PR$5,000
CITY OF RAHWAY DEPARTMENT OF PUBLIC WORKSRAHWAY, NJ$4,900
MATTRESS LIQUIDATORSEL PASO, TX$3,000

Free toolbox talk

A 5-minute crew talk on 1910.157(d), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.157(d).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How far can workers travel to a Class A extinguisher?

75 feet or less.

What about Class B hazards?

The travel distance from the Class B hazard area to any extinguisher must be 50 feet or less.

When are Class D extinguishers required?

In combustible metal working areas where combustible metal powders, flakes, shavings or similar products are generated at least once every two weeks, within 75 feet travel distance.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.