29 CFR 1910 · General Industry · Subpart Q

1910.253(b)(4): Safe Storage of Oxygen Cylinders

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 20, 2026 4 min read

In plain words:

Employers must store oxygen cylinders away from oil, grease, fuel-gas cylinders and other things that can start or speed up a fire. In storage, oxygen must be separated from fuel-gas cylinders or combustibles by at least 20 feet or by a noncombustible barrier at least 5 feet high with at least a half-hour fire rating, and large liquid oxygen systems must follow NFPA 566.

Key takeaways

  • 1910.253(b)(4) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart Q).
  • OSHA cited it 563 times in the last 3 years, in 559 inspections, with $1,085,275 in current penalties.
  • 2 deaths are linked to inspections that cited this rule.
  • Most citations: MD (58), NY (50), NJ (50).
  • Related part: 1910.253(b) Cylinders and containers (902 citations).
  • Free 5-minute toolbox talk for your crew below.
563citations, 3 years
$1,085,275current penalties
559inspections
2linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.253(b)(4) ("Oxygen storage") is one requirement inside 1910.253 Oxygen-fuel gas welding and cutting, an OSHA general industry standard (Part 1910, Subpart Q). It includes 4 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(4) Oxygen storage. 563 citations

(i) Oxygen cylinders shall not be stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment. Open (b)(4)(i) 92 citations

(ii) Oxygen cylinders stored in outside generator houses shall be separated from the generator or carbide storage rooms by a noncombustible partition having a fire-resistance rating of at least 1 hour. This partition shall be without openings and shall be gastight.

(iii) Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. Open (b)(4)(iii) 470 citations

(iv) Where a liquid oxygen system is to be used to supply gaseous oxygen for welding or cutting and the system has a storage capacity of more than 13,000 cubic feet (364 m3) of oxygen (measured at 14.7 psia (101 kPa) and 70 °F (21.1 °C)), connected in service or ready for service, or more than 25,000 cubic feet (700 m3) of oxygen (measured at 14.7 psia (101 kPa) and 70 °F (21.1 °C)), including unconnected reserves on hand at the site, it shall comply with the provisions of the Standard for Bulk Oxygen Systems at Consumer Sites, NFPA No. 566—1965, which is incorporated by reference as specified in § 1910.6.

Source: eCFR, text current as of 2026-10-15. Read all of 1910.253.

Injuries linked to this rule

2 deaths are linked to inspections where OSHA cited 1910.253(b)(4).

Employee is killed when crushed by conveyor while clearing d
2024-11-12 · Fatal · CLIFTON, NJ

At 2:30 p.m. on November 12, 2024, Employee #1, employed by a recycling company,was attempting to clear debris below a conveyor belt when the machine unexpectedly activated, causing the employee to be crushed. The employee suffered blunt trauma from the crushing incident and was later…

See all 2 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
202343
2024206
2025208
2026106

Top states: MD (58), NY (50), NJ (50), TN (35), MN (33)

Largest penalties

EmployerLocationPenalty for this rule
MAVIS TIRE SUPPLY LLCJACKSON, NJ$41,380
MONRO, INC.NORWICH, NY$40,000
FLORENCE HARDWOODS, LLCFLORENCE, WI$17,189
MARMON RETAIL SOLUTIONSWAGONER, OK$16,550
PB ACQUISITION COMPANY, LLCSOUTHINGTON, CT$16,131

Free toolbox talk

A 5-minute crew talk on 1910.253(b)(4), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How far must oxygen be stored from fuel gas?

At least 20 feet, or separated by a noncombustible barrier at least 5 feet high with a fire-resistance rating of at least one-half hour.

Why keep oxygen away from oil and grease?

Oil and grease are highly combustible, and oxygen can cause or accelerate fire. The rule specifically names them.

What about generator houses?

Oxygen cylinders stored in outside generator houses must be separated from generator or carbide storage rooms by a gastight noncombustible partition with at least a 1-hour fire rating.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top