In plain words:

Employers must keep cylinders, valves, regulators, hoses and apparatus free of oil and grease, and never let an oxygen jet strike an oily surface. Cylinders must be moved by crane only in a cradle or platform, not dropped or struck, kept capped and closed when moved, closed when work is finished, and kept far enough from welding or cutting that sparks, slag or flame cannot reach them.

Key takeaways

  • 1910.253(b)(5) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart Q).
  • OSHA cited it 16 times in the last 3 years, in 15 inspections, with $21,722 in current penalties.
  • Most citations: CO (2), MD (2), FL (1).
  • Related part: 1910.253(b) Cylinders and containers (902 citations).
  • Free 5-minute toolbox talk for your crew below.
16citations, 3 years
$21,722current penalties
15inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.253(b)(5) ("Operating procedures") is one requirement inside 1910.253 Oxygen-fuel gas welding and cutting, an OSHA general industry standard (Part 1910, Subpart Q). It includes 33 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(5) Operating procedures. 16 citations

(i) Cylinders, cylinder valves, couplings, regulators, hose, and apparatus shall be kept free from oily or greasy substances. Oxygen cylinders or apparatus shall not be handled with oily hands or gloves. A jet of oxygen must never be permitted to strike an oily surface, greasy clothes, or enter a fuel oil or other storage tank.

(ii) Open (b)(5)(ii) 11 citations

(A) When transporting cylinders by a crane or derrick, a cradle, boat, or suitable platform shall be used. Slings or electric magnets shall not be used for this purpose. Valve-protection caps, where cylinder is designed to accept a cap, shall always be in place. Open (b)(5)(ii)(a)

(B) Cylinders shall not be dropped or struck or permitted to strike each other violently. Open (b)(5)(ii)(b) 1 citations

(C) Valve-protection caps shall not be used for lifting cylinders from one vertical position to another. Bars shall not be used under valves or valve-protection caps to pry cylinders loose when frozen to the ground or otherwise fixed; the use of warm (not boiling) water is recommended. Valve-protection caps are designed to protect cylinder valves from damage.

(D) Unless cylinders are secured on a special truck, regulators shall be removed and valve-protection caps, when provided for, shall be put in place before cylinders are moved. Open (b)(5)(ii)(d) 4 citations

(E) Cylinders not having fixed hand wheels shall have keys, handles, or nonadjustable wrenches on valve stems while these cylinders are in service. In multiple cylinder installations only one key or handle is required for each manifold.

(F) Cylinder valves shall be closed before moving cylinders.

(G) Cylinder valves shall be closed when work is finished. 2 citations

(H) Valves of empty cylinders shall be closed.

(I) Cylinders shall be kept far enough away from the actual welding or cutting operation so that sparks, hot slag, or flame will not reach them, or fire-resistant shields shall be provided. Open (b)(5)(ii)(i) 3 citations

(J) Cylinders shall not be placed where they might become part of an electric circuit. Contacts with third rails, trolley wires, etc., shall be avoided. Cylinders shall be kept away from radiators, piping systems, layout tables, etc., that may be used for grounding electric circuits such as for arc welding machines. Any practice such as the tapping of an electrode against a cylinder to strike an arc shall be prohibited. 1 citations

(K) Cylinders shall never be used as rollers or supports, whether full or empty.

(L) The numbers and markings stamped into cylinders shall not be tampered with.

(M) No person, other than the gas supplier, shall attempt to mix gases in a cylinder. No one, except the owner of the cylinder or person authorized by him, shall refill a cylinder.

(N) No one shall tamper with safety devices in cylinders or valves.

(O) Cylinders shall not be dropped or otherwise roughly handled.

(P) Unless connected to a manifold, oxygen from a cylinder shall not be used without first attaching an oxygen regulator to the cylinder valve. Before connecting the regulator to the cylinder valve, the valve shall be opened slightly for an instant and then closed. Always stand to one side of the outlet when opening the cylinder valve.

(Q) A hammer or wrench shall not be used to open cylinder valves. If valves cannot be opened by hand, the supplier shall be notified.

(R)

(1) Cylinder valves shall not be tampered with nor should any attempt be made to repair them. If trouble is experienced, the supplier should be sent a report promptly indicating the character of the trouble and the cylinder's serial number. Supplier's instructions as to its disposition shall be followed.

(2) Complete removal of the stem from a diaphragm-type cylinder valve shall be avoided.

(iii) Open (b)(5)(iii) 5 citations

(A) Fuel-gas cylinders shall be placed with valve end up whenever they are in use. Liquefied gases shall be stored and shipped with the valve end up. Open (b)(5)(iii)(a) 1 citations

(B) Cylinders shall be handled carefully. Rough handling, knocks, or falls are liable to damage the cylinder, valve or safety devices and cause leakage. Open (b)(5)(iii)(b)

(C) Before connecting a regulator to a cylinder valve, the valve shall be opened slightly and closed immediately. The valve shall be opened while standing to one side of the outlet; never in front of it. Never crack a fuel-gas cylinder valve near other welding work or near sparks, flame, or other possible sources of ignition.

(D) Before a regulator is removed from a cylinder valve, the cylinder valve shall be closed and the gas released from the regulator.

(E) Nothing shall be placed on top of an acetylene cylinder when in use which may damage the safety device or interfere with the quick closing of the valve.

(F) If cylinders are found to have leaky valves or fittings which cannot be stopped by closing of the valve, the cylinders shall be taken outdoors away from sources of ignition and slowly emptied.

(G) A warning should be placed near cylinders having leaking fuse plugs or other leaking safety devices not to approach them with a lighted cigarette or other source of ignition. Such cylinders should be plainly tagged; the supplier should be promptly notified and his instructions followed as to their return.

(H) Safety devices shall not be tampered with. 1 citations

(I) Fuel-gas shall never be used from cylinders through torches or other devices equipped with shutoff valves without reducing the pressure through a suitable regulator attached to the cylinder valve or manifold. 1 citations

(J) The cylinder valve shall always be opened slowly.

(K) An acetylene cylinder valve shall not be opened more than one and one-half turns of the spindle, and preferably no more than three-fourths of a turn. 1 citations

(L) Where a special wrench is required it shall be left in position on the stem of the valve while the cylinder is in use so that the fuel-gas flow can be quickly turned off in case of emergency. In the case of manifolded or coupled cylinders at least one such wrench shall always be available for immediate use. 1 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.253.

Where and how often it was cited

YearCitations
20232
20246
20258

Top states: CO (2), MD (2), FL (1), HI (1), PR (1)

Largest penalties

EmployerLocationPenalty for this rule
VTCU, CORP.POCATELLO, ID$14,188
NATIONAL SALVAGE ENVIRONMENTAL SERVICES CORP.BLOOMINGTON, IN$1,950
ATLANTIC MAINTENANCE AND TRUCKING SERVICES, INC.CHRISTIANSTED, VI$1,844
STEEL SERVICES & SUPPLIES INC.TOA BAJA, PR$1,000
DUVINAGE LLCHAGERSTOWN, MD$890

Free toolbox talk

A 5-minute crew talk on 1910.253(b)(5), plus alerts when this rule changes. Free.




OSHA interpretation letters

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Can I handle oxygen cylinders with greasy gloves?

No. Oxygen cylinders or apparatus shall not be handled with oily hands or gloves.

How must cylinders be lifted by crane?

With a cradle, boat, or suitable platform; slings or electric magnets shall not be used.

Can I lift a cylinder by its valve cap?

No. Valve-protection caps shall not be used for lifting cylinders from one vertical position to another.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top