29 CFR 1910 · General Industry · Subpart R

1910.268(m)(3)(i): Treat Nearby Power Conduit and Fixtures as Energized

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated November 17, 2026 3 min read

In plain words:

On joint use poles, metal power conduit, exposed vertical power ground wires and street light fixtures that are below communications attachments, or less than 20 inches above them, must be considered energized. They must be tested for voltage unless the employee can visually determine they are bonded to the communications suspension strand or cable sheath.

Key takeaways

  • 1910.268(m)(3)(i) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart R).
  • OSHA cited it 1 times in the last 3 years, in 1 inspections, with $14,068 in current penalties.
  • 1 death is linked to inspections that cited this rule.
  • Related part: 1910.268(m)(3) Vertical power conduit, power ground wires and street light fixtures (1 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.268(m)(3)(i) ↓

1citations, 3 years
$14,068current penalties
1inspections
1linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Related parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.268(m)(3)(i) is one requirement inside 1910.268 Telecommunications, an OSHA general industry standard (Part 1910, Subpart R). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(i) Metal power conduit on joint use poles, exposed vertical power ground wires, and street light fixtures which are below communications attachments or less than 20 inches above these attachments, shall be considered energized and shall be tested for voltage unless the employee can visually determine that they are bonded to the communications suspension strand or cable sheath. 1 citations

Source: eCFR, text current as of 2026-10-15. Read all of 1910.268.

See every company cited for this rule.

Export the list: 1 inspections cited 1910.268(m)(3)(i) in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Injuries linked to this rule

1 death is linked to inspections where OSHA cited 1910.268(m)(3)(i).

Employee experiences fatal medical event in bucket truck
2024-10-22 · Fatal · ASHLAND, AL

At 1:30 p.m. on October 22, 2024, Employee #1, a fiber optic cable installer, was elevated in a bucket truck at a joint-use utility pole located in Ashland, Alabama. He was preparing to lower a coil of fiber to the ground for splicing when he…

Where and how often it was cited

Free toolbox talk

A 5-minute crew talk on 1910.268(m)(3)(i), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.268(m)(3)(i).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Which fixtures must be tested for voltage?

Metal power conduit, exposed vertical power ground wires and street light fixtures below communications attachments or less than 20 inches above them.

When can the voltage test be skipped?

When the employee can visually determine the item is bonded to the communications suspension strand or cable sheath.

Where does this rule apply?

On joint use poles.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top