1910.268(m)(3): Test or Bond Power Conduit and Street Lights
On joint use poles, metal power conduit, exposed vertical power ground wires and street light fixtures that are below communications attachments, or less than 20 inches above them, must be treated as energized and tested for voltage unless the employee can see they are bonded to the strand or cable sheath. If no hazardous voltage is found, a temporary bond carrying at least 500 amperes for one second without fusing must be placed to the communications cable strand.
Key takeaways
- 1910.268(m)(3) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart R).
- OSHA cited it 1 times in the last 3 years, in 1 inspections, with $14,068 in current penalties.
- 1 death is linked to inspections that cited this rule.
- Related part: 1910.268(m)(3)(i) (1 citations).
- Free 5-minute toolbox talk for your crew below.
Get the free 5-minute toolbox talk on 1910.268(m)(3) ↓
In this article
What this rule covers
29 CFR 1910.268(m)(3) ("Vertical power conduit, power ground wires and street light fixtures") is one requirement inside 1910.268 Telecommunications, an OSHA general industry standard (Part 1910, Subpart R). It includes 2 sub-paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.
Official text
(3) Vertical power conduit, power ground wires and street light fixtures. 1 citations
(i) Metal power conduit on joint use poles, exposed vertical power ground wires, and street light fixtures which are below communications attachments or less than 20 inches above these attachments, shall be considered energized and shall be tested for voltage unless the employee can visually determine that they are bonded to the communications suspension strand or cable sheath. Open (m)(3)(i) 1 citations
(ii) If no hazardous voltage is shown by the voltage test, a temporary bond shall be placed between such street light fixture, exposed vertical power grounding conductor, or metallic power conduit and the communications cable strand. Temporary bonds used for this purpose shall have sufficient conductivity to carry at least 500 amperes for a period of one second without fusing.
Source: eCFR, text current as of 2026-10-15. Read all of 1910.268.
Export the list: 1 inspections cited 1910.268(m)(3) in the last 3 years, with employer, location, penalty and date.
Purple Belt, $59/moInjuries linked to this rule
1 death is linked to inspections where OSHA cited 1910.268(m)(3).
At 1:30 p.m. on October 22, 2024, Employee #1, a fiber optic cable installer, was elevated in a bucket truck at a joint-use utility pole located in Ashland, Alabama. He was preparing to lower a coil of fiber to the ground for splicing when he…
Where and how often it was cited
Free toolbox talk
A 5-minute crew talk on 1910.268(m)(3), plus alerts when this rule changes. Free.
OSHA interpretation letters
None exist. OSHA has not published a letter of interpretation for 1910.268(m)(3).
Related parts of this rule
- 1910.268(m)(3)(i) 1 citations
- 1910.268(m) Grounding for employee protection—pole lines 1 citations
Get your crew competent
Trainers on Black Belt Safety: Marc Harvey
Trainers and suppliers: feature your business on this rule for $25/month.
Frequently asked questions
Which items must be treated as energized?
Metal power conduit, exposed vertical power ground wires and street light fixtures below communications attachments or less than 20 inches above them.
What happens if no hazardous voltage is found?
A temporary bond must be placed between the item and the communications cable strand.
How strong must the temporary bond be?
It must carry at least 500 amperes for a period of one second without fusing.
About this page
Sources
- 29 CFR 1910.268 (eCFR), text current as of 2026-10-15
- U.S. Department of Labor enforcement data: OSHA inspections, citations and accident records, copied nightly; data as of 2026-11-17
3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.