29 CFR 1910 · General Industry · Subpart S

1910.304(b)(3)(ii)(A): GFCI Protection for Temporary Receptacles

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated October 20, 2026 3 min read

In plain words:

Employers must provide ground-fault circuit-interrupter (GFCI) protection on all 125-volt, single-phase, 15-, 20- and 30-ampere receptacle outlets that are not part of the building's permanent wiring and are in use by workers. An extension cord connector counts as a receptacle if the cord set is used for temporary power, and GFCI cord sets plugged into the receptacle closest to the power source are acceptable.

Key takeaways

  • 1910.304(b)(3)(ii)(A) is part of OSHA's general industry standards (29 CFR Part 1910, Subpart S).
  • OSHA cited it 10 times in the last 3 years, in 10 inspections, with $36,327 in current penalties.
  • Most citations: TX (2), IL (1), KY (1).
  • Related part: 1910.304(b) Branch circuits (279 citations).
  • Free 5-minute toolbox talk for your crew below.
10citations, 3 years
$36,327current penalties
10inspections
0linked injury cases
In this article
  1. What this rule covers
  2. Official text
  3. Where and how often it was cited
  4. Free toolbox talk
  5. OSHA interpretation letters
  6. Related parts of this rule
  7. Get your crew competent
  8. Frequently asked questions
  9. About this page

What this rule covers

29 CFR 1910.304(b)(3)(ii)(A) is one requirement inside 1910.304 Wiring design and protection, an OSHA general industry standard (Part 1910, Subpart S). The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

(A) All 125-volt, single-phase,15-, 20-, and 30-ampere receptacle outlets that are not part of the permanent wiring of the building or structure and that are in use by personnel shall have ground-fault circuit-interrupter protection for personnel. 10 citations

A cord connector on an extension cord set is considered to be a receptacle outlet if the cord set is used for temporary electric power.

Cord sets and devices incorporating the required ground-fault circuit-interrupter that are connected to the receptacle closest to the source of power are acceptable forms of protection.

Source: eCFR, text current as of 2026-10-15. Read all of 1910.304.

Where and how often it was cited

YearCitations
20231
20243
20254
20262

Top states: TX (2), IL (1), KY (1), RI (1), OR (1)

Largest penalties

EmployerLocationPenalty for this rule
EAST COAST REPAIR AND FABRICATION, LLCNEWPORT NEWS, VA$8,044
BRENNTAG GREAT LAKES, LLCDES MOINES, IA$7,034
NGC, INC.NARRAGANSETT, RI$6,964
BALANCED ENVIRONMENTS, INC.WHEELING, IL$5,000
FIRST MARINE, LLCCALVERT CITY, KY$4,969

Free toolbox talk

A 5-minute crew talk on 1910.304(b)(3)(ii)(A), plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.304(b)(3)(ii)(A).

Related parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey, Dana Reyes

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

Which outlets need GFCI protection under this rule?

All 125-volt, single-phase, 15-, 20- and 30-ampere receptacle outlets that are not part of the permanent wiring and are in use by personnel.

Does an extension cord count as a receptacle?

Yes, the cord connector counts as a receptacle outlet if the cord set is used for temporary electric power.

Can I use a GFCI cord set instead of a GFCI outlet?

Yes. Cord sets and devices with the required GFCI connected to the receptacle closest to the power source are acceptable.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top