29 CFR 1910 · General Industry · Subpart E

1910.36: Exit Route Design and Construction

By Black Belt Safety Editorial Team Official text as of October 15, 2026 Data updated November 6, 2026 3 min read

In plain words:

Employers must make sure exit routes are a permanent part of the workplace, and that exits are separated by fire resistant materials with only necessary openings protected by self-closing fire doors. Workplaces need at least two exit routes placed as far apart as practical, or more if needed, and each exit must discharge directly outside or to a safe open area.

Key takeaways

  • 1910.36 is part of OSHA's general industry standards (29 CFR Part 1910, Subpart E).
  • OSHA cited it 1,084 times in the last 3 years, in 1,001 inspections, with $3,265,634 in current penalties.
  • 4 deaths are linked to inspections that cited this rule.
  • Most citations: PR (114), NY (84), TN (79).
  • Most-cited part: 1910.36(d) An exit door must be unlocked (528 citations).
  • Free 5-minute toolbox talk for your crew below.

Get the free 5-minute toolbox talk on 1910.36 ↓

1,084citations, 3 years
$3,265,634current penalties
1,001inspections
4linked deaths
In this article
  1. What this rule covers
  2. Official text
  3. Injuries linked to this rule
  4. Where and how often it was cited
  5. Free toolbox talk
  6. OSHA interpretation letters
  7. Most-cited parts of this rule
  8. Get your crew competent
  9. Frequently asked questions
  10. About this page

What this rule covers

29 CFR 1910.36, "Design and construction requirements for exit routes", is an OSHA general industry standard (Part 1910, Subpart E). It has 32 numbered paragraphs. The official text below is copied word for word from the Electronic Code of Federal Regulations (eCFR). The numbers, injury cases and training on this page show how OSHA enforces it on real job sites.

Official text

Show the full text of 1910.36 (32 paragraphs)

(a) Basic requirements. Exit routes must meet the following design and construction requirements: Open (a) 18 citations

(1) An exit route must be permanent. Each exit route must be a permanent part of the workplace. 1 citations

(2) An exit must be separated by fire resistant materials. Construction materials used to separate an exit from other parts of the workplace must have a one-hour fire resistance-rating if the exit connects three or fewer stories and a two-hour fire resistance-rating if the exit connects four or more stories. 4 citations

(3) Openings into an exit must be limited. An exit is permitted to have only those openings necessary to allow access to the exit from occupied areas of the workplace, or to the exit discharge. An opening into an exit must be protected by a self-closing fire door that remains closed or automatically closes in an emergency upon the sounding of a fire alarm or employee alarm system. Each fire door, including its frame and hardware, must be listed or approved by a nationally recognized testing laboratory. Section 1910.155(c)(3)(iv)(A) of this part defines “listed” and § 1910.7 of this part defines a “nationally recognized testing laboratory.” Open (a)(3) 13 citations

(b) The number of exit routes must be adequate — Open (b) 26 citations

(1) Two exit routes. At least two exit routes must be available in a workplace to permit prompt evacuation of employees and other building occupants during an emergency, except as allowed in paragraph (b)(3) of this section. The exit routes must be located as far away as practical from each other so that if one exit route is blocked by fire or smoke, employees can evacuate using the second exit route. Open (b)(1) 24 citations

(2) More than two exit routes. More than two exit routes must be available in a workplace if the number of employees, the size of the building, its occupancy, or the arrangement of the workplace is such that all employees would not be able to evacuate safely during an emergency. 2 citations

(3) A single exit route. A single exit route is permitted where the number of employees, the size of the building, its occupancy, or the arrangement of the workplace is such that all employees would be able to evacuate safely during an emergency.

For assistance in determining the number of exit routes necessary for your workplace, consult NFPA 101-2009, Life Safety Code, or IFC-2009, International Fire Code (incorporated by reference, see § 1910.6).

(c) Exit discharge. Open (c) 25 citations

(1) Each exit discharge must lead directly outside or to a street, walkway, refuge area, public way, or open space with access to the outside. Open (c)(1) 20 citations

(2) The street, walkway, refuge area, public way, or open space to which an exit discharge leads must be large enough to accommodate the building occupants likely to use the exit route. Open (c)(2) 2 citations

(3) Exit stairs that continue beyond the level on which the exit discharge is located must be interrupted at that level by doors, partitions, or other effective means that clearly indicate the direction of travel leading to the exit discharge. 3 citations

(d) An exit door must be unlocked. Open (d) 528 citations

(1) Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors. Open (d)(1) 499 citations

(2) Exit route doors must be free of any device or alarm that could restrict emergency use of the exit route if the device or alarm fails. Open (d)(2) 17 citations

(3) An exit route door may be locked from the inside only in mental, penal, or correctional facilities and then only if supervisory personnel are continuously on duty and the employer has a plan to remove occupants from the facility during an emergency. 7 citations

(e) A side-hinged exit door must be used. Open (e) 45 citations

(1) A side-hinged door must be used to connect any room to an exit route. Open (e)(1) 25 citations

(2) The door that connects any room to an exit route must swing out in the direction of exit travel if the room is designed to be occupied by more than 50 people or if the room is a high hazard area (i.e., contains contents that are likely to burn with extreme rapidity or explode). Open (e)(2) 20 citations

(f) The capacity of an exit route must be adequate.

(1) Exit routes must support the maximum permitted occupant load for each floor served.

(2) The capacity of an exit route may not decrease in the direction of exit route travel to the exit discharge.

Information regarding the “Occupant load” is located in NFPA 101-2009, Life Safety Code, and in IFC-2009, International Fire Code (incorporated by reference, see § 1910.6).

(g) An exit route must meet minimum height and width requirements. Open (g) 411 citations

(1) The ceiling of an exit route must be at least seven feet six inches (2.3 m) high. Any projection from the ceiling must not reach a point less than six feet eight inches (2.0 m) from the floor. Open (g)(1) 9 citations

(2) An exit access must be at least 28 inches (71.1 cm) wide at all points. Where there is only one exit access leading to an exit or exit discharge, the width of the exit and exit discharge must be at least equal to the width of the exit access. Open (g)(2) 362 citations

(3) The width of an exit route must be sufficient to accommodate the maximum permitted occupant load of each floor served by the exit route.

(4) Objects that project into the exit route must not reduce the width of the exit route to less than the minimum width requirements for exit routes. Open (g)(4) 40 citations

(h) An outdoor exit route is permitted. Each outdoor exit route must meet the minimum height and width requirements for indoor exit routes and must also meet the following requirements: Open (h) 31 citations

(1) The outdoor exit route must have guardrails to protect unenclosed sides if a fall hazard exists; 5 citations

(2) The outdoor exit route must be covered if snow or ice is likely to accumulate along the route, unless the employer can demonstrate that any snow or ice accumulation will be removed before it presents a slipping hazard; Open (h)(2) 12 citations

(3) The outdoor exit route must be reasonably straight and have smooth, solid, substantially level walkways; and Open (h)(3) 13 citations

(4) The outdoor exit route must not have a dead-end that is longer than 20 feet (6.2 m). 1 citations

[67 FR 67961, Nov. 7, 2002, as amended at 76 FR 33606, June 8, 2011]

Source: eCFR, text current as of 2026-10-15.

See every company cited for this rule.

Export the list: 1,001 inspections cited 1910.36 in the last 3 years, with employer, location, penalty and date.

Purple Belt, $59/mo

Injuries linked to this rule

4 deaths are linked to inspections where OSHA cited 1910.36.

Employee is killed when caught between front-end loader and
2024-11-20 · Fatal · TOLLESON, AZ

At 9:40 a.m. on November 20, 2024, an employee was operating a forklift outside the cattle pens at the paunch pad area, dumping dry paunch (powder texture) ontothe floor. During this time, a subcontracted employee was operating a front-end loader in close proximity, loading paunch…

See all 4 cases

Full case list with employer, penalty, filters and download is part of OSHA Data (Purple Belt).

Unlock with Purple Belt

Where and how often it was cited

YearCitations
202343
2024420
2025359
2026262

Top states: PR (114), NY (84), TN (79), VA (65), AZ (53)

Largest penalties

EmployerLocationPenalty for this rule
KRAFT HEINZMUSCATINE, IA$110,000
DOLLAR TREE STORES, INC; STORE #4457ANNANDALE, VA$92,245
U.S. POSTAL SERVICE - ISANTIISANTI, MN$85,116
DOLLAR TREE INCALEXANDRIA, VA$84,945
DOLLAR TREE, INC.VIRGINIA BEACH, VA$68,825

Free toolbox talk

A 5-minute crew talk on 1910.36, plus alerts when this rule changes. Free.




OSHA interpretation letters

None exist. OSHA has not published a letter of interpretation for 1910.36.

Most-cited parts of this rule

Get your crew competent

Trainers on Black Belt Safety: Marc Harvey

Trainers and suppliers: feature your business on this rule for $25/month.

Frequently asked questions

How many exit routes does a workplace need?

At least two, as far apart as practical. More are needed if employees could not all get out safely, and one is allowed only if everyone could evacuate safely with it.

What fire rating must exit separations have?

One-hour fire resistance if the exit connects three or fewer stories, and two-hour if it connects four or more stories.

Where must an exit lead?

Directly outside, or to a street, walkway, refuge area, public way or open space with access to the outside.

About this page

Sources

3-year window. Federal OSHA only; state-plan rules are not counted. Plain-language text is a summary, not legal advice; the official text controls. Black Belt Safety is not part of OSHA or the Department of Labor.

Written and reviewed by

Black Belt Safety Editorial Team

Site Safety Officer and Safety Professional

OSHA 30 · CPR · USACE CQM

Written and reviewed by the Black Belt Safety team. Every post is checked against the OSHA standard or agency source it cites.

Scroll to top